Illustra Flex Series Installation and Configuration Guide
8200-1456-01 D0
81
•
TemperatureTooHigh (Warning)
- this fault is raised when the internal temperature of the
enclosure is equal to or exceeds the value MAX_TEMPERATURE held in ENVM.conf.
Once an alarm is generated and the temperature drops to a level 1 degree below the MAX_
TEMPERATURE value the fault is then automatically cleared. This is to avoid transient
changes in temperature around the threshold.
•
TemperatureTooLow (Warning)
- a fault is raised when the internal temperature of the
enclosure is equal to or is below the value MIN_TEMPERATURE held in ENVM.conf.
Once an alarm is generated and the temperature drops to a level 1 degree above the MIN_
TEMPERATURE value the fault is then automatically cleared. This is to avoid transient
changes in temperature around the threshold.
Procedure 94 Display Current Faults
Step Action
1
Select
Setup
on the Web User Interface banner to display the setup menus.
2
Select
Event Logs
from the
Event and Actions
menu.
3
Select the
Fault Log
tab.
- End -
Procedure 95 Delete Current Faults
Step Action
1
Select
Setup
on the Web User Interface banner to display the setup menus.
2
Select
Event Logs
from the
Events and Actions
menu.
3
Select the
Fault Log
tab.
4
Select the corresponding
Delete
check box to mark the fault for deletion.
OR
Clear the corresponding
Delete
check box to keep the fault.
Note:
You can select the
Select All
check box to mark all faults displayed in the list
for deletion.
5
Select
Delete
to delete the selected faults.
You are prompted to confirm the deletion.
6
Select
OK
to confirm the deletion.
OR
Select
Cancel
.
- End -
Security
When you select the
Security
menu, the
Security Status
page appears, as seen in Figure 56 on
page 82.