AC power on shall be indicated by an external panel mount LED (Lumex SSI-LXH312GD-150) and fitted into
a dedicated 4mm hole in the cabinet to provide external visibility. This shall be wired between 12V and a
PGM output that is programmed to follow the AC trouble input as shown below:
BZ
L1 D1 DO
LED
V+
V-
Z4
V- Z3
Z2
V- Z1
1K5 OHM
READER 1
ZONE INPUT 1-4
12VDC OUT
If a flexible cord is used to connect to line voltage, strain relief must be provided for the cord inside the
enclosure or at the knockout.
The Power Supply is not intended to be mounted on the exterior of vault, safe, or stockroom.