CRX-POSTX-DIN
DIN Rail PostX IP Reporting Module
Installation Manual | June 2017
41
Command
Example
Description
set ntpl
set ntpl 202.156.2.125
Sets the primary SNTP server. The PostX must be
restarted for the change to take effect
sntp
sntp 202.156.2.125
Updates the time from the SNTP server at the given IP
address. This can be used to confirm the SNTP server is
working before you save it in the network configuration.
system
system
Displays the system details including serial number and
software version
time
time
Displays the current time stored in the PostX
wifi default
wifi default
Resets the WIFI parameters to factory defaults
wifi reset
wifi reset
Restarts the WIFI module
wifi set ssid
wifi set ssid ICT
Sets the SSID parameter (case sensitive) of the WIFI
module
wifi set password
wifi set password 1234ab
Sets the access point password key of the WIFI module
wifi status
wifi status
Displays the WIFI interface status,
connected/disconnected, the connection duration time
and the signal strength x/4.