26
CRX-POSTX-DIN
DIN Rail PostX IP Reporting Module
Installation Manual | June 2017
Primary WiFi Gateway Failure
Secondary WiFi Gateway Failure
If more than one option is selected, use the OR/AND conditions to determine if at least one of them or all of
them have to be met in order to activate.
Receive SMS Activation
The output can also be activated/deactivated via a SMS message. The SMS format to be used is as
follows:
<activation
password>
<output
name>
<action>
<ack>
The PostX module is not case sensitive. The following table describes the control word:
Action
Code
Turn PGM ON
on
,
On
,
ON
, or
1
Turn PGM OFF
off
,
Off
,
OFF
, or
0
Acknowledge SMS
ack
,
Ack
,
ACK
,
a
,
A
or
1
For the following examples, PGM 1 has been set with validate by pin, acknowledge by request and the
command
garage
. PGM 2 has been set with validate by any, no acknowledge and the command
gate
.
This pin code has been set to
house
.
SMS Message
Action
house garage on ack
PGM 1 turned on, and acknowledge SMS sent
house garage off a
PGM 1 turned off, and acknowledge SMS sent
garage on ack
No action taken, pin code (house) not entered
house garage 1 1
PGM 1 turned on, and acknowledge SMS sent
gate on ack
PGM 2 turned on, and acknowledge SMS sent
gate 1
PGM 2 turned on, no acknowledge SMS sent
house garage 1 1 gate 1
PGM 1 turned on, and acknowledge SMS sent, gate is not handled, a
separate SMS has to be used
If the Enable password option is set, the SMS control requires the Activation password to be correct for any
operation to be performed. The activation password is sent at the start of the message. For example, if the
activation password set was
123abcd
you would send
123abcd
garage
on
ack
to open the garage
door. If the activation password is wrong, no response is sent to the user even if an acknowledgment is
requested.