For the settings shown above, when the input opens, the following SMS will be sent by the PostX Module:
Site Name:
ICT PostX Module
Zone Message:
Zone 1 (Zone 1) Opened
Time Stamp:
13:00:26 27/02/2013
Programmable Outputs
The PostX Module has 2 programmable outputs. These outputs can be configured to be activated when the
PostX Module loses a connection. Additionally, the outputs can be used to activate bell sirens, lighting circuits,
door locks, relay accessory products and other automation points through SMS messages.
i
In order to enter any of the IP troubleshooting modes, Relay 1 on the PostX Module will enable briefly
on startup. To prevent this from occurring, ensure that at least one of the zone inputs is wired directly
to V-.
The 2 Outputs each have a FORM C output relay. The connection example below shows the control of an
external LED indicator.
1K5 OHM
+12V AUX
0V
LED
V+
V-
NC
C
NO
NC
C
NO
Output Connection (Output 2 Shown)
Warning: Switching inductive loads that can produce high back EMF voltages or large voltage
induced spikes can cause the PostX Module to behave unexpectedly and should be avoided. A
suitable isolation circuit must be installed between the relay contacts of the PostX Module and the
inductive load.