message will be present in the log. If multiple temperature warning messages were
sent to the log, the latest one will replace the previous one. The static buffer is not
configurable.
The message types that appear in the static buffer do not appear in the dynamic
buffer. The dynamic buffer contains up to the maximum number of messages
configured for the buffer (50 by default), then begins removing the oldest messages
(at the bottom of the log) to make room for new ones.
The static and dynamic buffers are both displayed when you display the log.
(config)# show logging
...
Static Log Buffer:
Aug 27 12:42:42:A:Power Supply 6, 1st right, failed
Dynamic Log Buffer (50 lines):
Aug 27 12:19:04:I:Interface ethernet3/4, state up
Aug 27 12:19:04:I:Interface ethernet6/3, state up
Aug 27 12:19:04:I:Interface ethernet3/2, state up
Aug 27 12:19:04:I:Interface ethernet6/1, state up
Aug 27 12:19:00:N:Module up in slot 6
Aug 27 12:19:00:N:Module up in slot 3
Aug 27 12:18:43:I:Warm start
When you clear log entries, you can selectively clear the static or dynamic buffer, or
you can clear both. for example, to clear only the dynamic buffer, enter the following
command at the Privileged EXEC level:
# clear logging dynamic-buffer
Syntax:
clear logging [dynamic-buffer | static-buffer]
You can specify the
dynamic-buffer
keyword to clear the dynamic buffer or the
static-buffer
keyword to clear the static buffer. If you do not specify a buffer, both
buffers are cleared.
Syntax:
show log
Syslog messages for PCI (hardware) errors
Chassis devices support the display of PCI (hardware) read and write errors
encountered on a slot/module during bootup and during normal system operations.
There are four types of PCI errors, which may cause the system to disable/power
down the module(s) on which they occur:
v
Configuration read error
v
Configuration write error
v
Memory read error
v
Memory write error
For more information, see the
Configuration Guide
.
Managing the switch fabric modules
If desired, you can disable power to a switch fabric module and then reenable it. To
disable the power, enter the following command at the Privileged EXEC level of the
CLI:
# disable switch-fabric 1
Chapter 5. Managing the Chassis and Modules
71
Содержание s-series
Страница 1: ...IBM Ethernet Switch s series Installation and User Guide Service information 4003 S08 S16 GC27 2243 00...
Страница 2: ......
Страница 3: ...IBM Ethernet Switch s series Installation and User Guide Service information 4003 S08 S16 GC27 2243 00...
Страница 10: ...viii Ethernet Switch s series Installation and User Guide...
Страница 14: ...xii Ethernet Switch s series Installation and User Guide...
Страница 28: ...2 Ethernet Switch s series Installation and User Guide...
Страница 52: ...26 Ethernet Switch s series Installation and User Guide...
Страница 65: ...Figure 24 Connecting AC power to a B08S Chapter 3 Installing the Chassis 39...
Страница 70: ...44 Ethernet Switch s series Installation and User Guide...
Страница 100: ...74 Ethernet Switch s series Installation and User Guide...
Страница 116: ...90 Ethernet Switch s series Installation and User Guide...
Страница 139: ...Figure 52 Location of AC power connection on B08S Chapter 7 Maintaining the hardware 113...
Страница 146: ...120 Ethernet Switch s series Installation and User Guide...
Страница 164: ...138 Ethernet Switch s series Installation and User Guide...
Страница 169: ......
Страница 170: ...Part Number 45W3125 Printed in USA GC27 2243 00 1P P N 45W3125 80214 001...