FastIron# show chassis
...
Fan controlled temperature:
Rule 1/3 (MGMT CARDS THERMAL PLANE): 55.5 deg-C...
Rule 2/3 (LINE CARDS THERMAL PLANE): 59.6 deg-C...
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE): 78.7 deg-C...
Syntax: show chassis
Displaying fan status and speed
The
show chassis
command displays the status and speed of the fans in the
chassis. The following shows an example output which supports four fan speeds.
# show chassis
...
Fan 1 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 2 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 3 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 4 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 5 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 6 ok, speed (auto): 1<->[[2]]<->3<->4
Syntax:
show chassis
For each fan, the display shows the following information:
Table 23. Information displayed regarding fan status
Field
Display
Status
The status of the fan. This field can be one of the following:
OK - The fan is functioning properly and is keeping the temperature of each module
within an acceptable temperature range.
Failed - The fan is not functioning properly or the fan control module cannot control the
fan.
Speed
The speed at which the fan is currently operating (denoted by double brackets).
1 (low) - The fan is functioning at 25 percent of capacity.
2 (medium-low) - The fan is functioning at 37 percent of capacity.
3 (medium) - The fan is functioning at 50 percent of capacity.
4 (high) - The fan is functioning at 100 percent of capacity.
NOTE:
If the report shows that a fan has
failed
, the report does not show the fan’s
speed.
Displaying temperature warnings
If the temperature of a module exceeds the high temperature threshold for any of
the fan speeds, the system sends a message to the system log. This section
describes how to view the system log. If you have configured the system to use a
Syslog server, see the documentation for the server or receiver.
To display the system log, enter the following command at any CLI level:
# show log
...
Dynamic Log Buffer (50 lines):
Chapter 5. Managing the Chassis and Modules
69
Содержание s-series
Страница 1: ...IBM Ethernet Switch s series Installation and User Guide Service information 4003 S08 S16 GC27 2243 00...
Страница 2: ......
Страница 3: ...IBM Ethernet Switch s series Installation and User Guide Service information 4003 S08 S16 GC27 2243 00...
Страница 10: ...viii Ethernet Switch s series Installation and User Guide...
Страница 14: ...xii Ethernet Switch s series Installation and User Guide...
Страница 28: ...2 Ethernet Switch s series Installation and User Guide...
Страница 52: ...26 Ethernet Switch s series Installation and User Guide...
Страница 65: ...Figure 24 Connecting AC power to a B08S Chapter 3 Installing the Chassis 39...
Страница 70: ...44 Ethernet Switch s series Installation and User Guide...
Страница 100: ...74 Ethernet Switch s series Installation and User Guide...
Страница 116: ...90 Ethernet Switch s series Installation and User Guide...
Страница 139: ...Figure 52 Location of AC power connection on B08S Chapter 7 Maintaining the hardware 113...
Страница 146: ...120 Ethernet Switch s series Installation and User Guide...
Страница 164: ...138 Ethernet Switch s series Installation and User Guide...
Страница 169: ......
Страница 170: ...Part Number 45W3125 Printed in USA GC27 2243 00 1P P N 45W3125 80214 001...