Chapter 5. Managing the Chassis and Modules
This chapter contains information about refining the configuration of, monitoring,
and managing the hardware components.
Displaying chassis status and temperature readings
You can display the following information related to the chassis:
v
Status of the power supplies
v
Status of the fans
v
Temperature readings and thresholds of the management and interface modules
v
Temperature readings and thresholds of the switch fabric modules.
v
The MAC address of the chassis
The following shows an example of the
show chassis
command output on the
B08S. The display is similar on the running software release 03.0.00 or later.
SX 800 Router#show chassis
Chassis Type: SX 800
Power supply 1 not present
Power supply 2 not present
Power supply 3 (H1250C - AC - Regular) present, status ok
Power supply 4 not present
Fan 1 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 2 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 3 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 4 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 5 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 6 ok, speed (auto): 1<->[[2]]<->3<->4
Fan controlled temperature:
Rule 1/3 (MGMT CARDS THERMAL PLANE): 41.5 deg-C
Rule 2/3 (LINE CARDS THERMAL PLANE): 44.0 deg-C
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE): 49.5 deg-C
Fan speed switching temperature thresholds:
Rule 1/3 (MGMT CARDS THERMAL PLANE):
Speed 1: NM<----->57 deg-C
Speed 2: 48<----->58 deg-C
Speed 3: 49<----->59 deg-C
Speed 4: 50<----->80 deg-C (shutdown)
Rule 2/3 (LINE CARDS THERMAL PLANE):
Speed 1: NM<----->57 deg-C
Speed 2: 48<----->58 deg-C
Speed 3: 49<----->59 deg-C
Speed 4: 50<----->80 deg-C (shutdown)
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE)***active***:
Speed 1: NM<----->57 deg-C
Speed 2: 48<----->58 deg-C
Speed 3: 49<----->59 deg-C
Speed 4: 50<----->80 deg-C (shutdown)
Slot 1 Temperature: 44.0 deg-C
Slot 2 Temperature: 34.5 deg-C
Slot 3 Temperature: empty
Slot 4 Temperature: 39.5 deg-C
Slot 5 Temperature: empty
Slot 6 Temperature: empty
Slot 7 Temperature: empty
Slot 8 Temperature: empty
Slot 9 Temperature: 39.0 deg-C
© Copyright IBM Corp. 2009
57
Содержание s-series
Страница 1: ...IBM Ethernet Switch s series Installation and User Guide Service information 4003 S08 S16 GC27 2243 00...
Страница 2: ......
Страница 3: ...IBM Ethernet Switch s series Installation and User Guide Service information 4003 S08 S16 GC27 2243 00...
Страница 10: ...viii Ethernet Switch s series Installation and User Guide...
Страница 14: ...xii Ethernet Switch s series Installation and User Guide...
Страница 28: ...2 Ethernet Switch s series Installation and User Guide...
Страница 52: ...26 Ethernet Switch s series Installation and User Guide...
Страница 65: ...Figure 24 Connecting AC power to a B08S Chapter 3 Installing the Chassis 39...
Страница 70: ...44 Ethernet Switch s series Installation and User Guide...
Страница 100: ...74 Ethernet Switch s series Installation and User Guide...
Страница 116: ...90 Ethernet Switch s series Installation and User Guide...
Страница 139: ...Figure 52 Location of AC power connection on B08S Chapter 7 Maintaining the hardware 113...
Страница 146: ...120 Ethernet Switch s series Installation and User Guide...
Страница 164: ...138 Ethernet Switch s series Installation and User Guide...
Страница 169: ......
Страница 170: ...Part Number 45W3125 Printed in USA GC27 2243 00 1P P N 45W3125 80214 001...