Ethernet Controller Messages
PCNTNW-OS2-58 The board did not respond to the initialization command.
Explanation:
The IRQ setting might be incorrect with the hardware setting, or the
EEPROM might be corrupted.
Action:
Verify that the IRQ settings in the NET.CFG file match the configuration
settings in the Configuration/Setup utility programs. See “PCI Bus Control” on
page 33 for information on setting the interrupt requests. Verify that the EEPROM
on the system board is programmed correctly.
PCNTNW-OS2-61 PCI device IRQ number mismatch.
Explanation:
The IRQ number specified in the NET.CFG file does not match with
the IRQ number assigned in the Configuration/Setup utility programs. The IRQ
numbers might be assigned automatically, or you might have manually assigned the
IRQ number.
Action:
Remove the IRQ number in the NET.CFG file. Or, see “PCI Bus Control” on
page 33 for information on setting the interrupt requests.
PCNTNW-OS2-64 The device was not found.
Explanation:
The driver cannot find the Ethernet contoller in the server.
Action:
Verify that the Ethernet enable jumper is set to the default (enable) position.
Go to “About the Test Programs” on page 129 to run the diagnostic utility.
PCNTNW-OS2-65 Device not found at IOADDRESS.
Explanation:
The Ethernet controller cannot be found at the IO address specified in
the NET.CFG file.
Action:
Verify that the IO address in NET.CFG matches with the board. Otherwise,
remove the PORT keyword from the NET.CFG file.
PCNTNW-OS2-67 PCI scan specified, device not found.
Explanation:
The driver cannot locate the Ethernet controller on the PCI bus.
Action:
Perform the following steps:
1. Verify that the Ethernet jumper on the system board is set to the default, enable
position.
2. Edit the NET.CFG file to change the BUSTYPE keyword to PCI1.
3. If the problem persists, go to “About the Test Programs” on page 129 to run the
diagnostic utility.
PCNTNW-OS2-73 Unable to allocate memory.
Explanation:
The driver could not allocate memory for the virtual board.
Action:
Check the system configuration.
164
PC Server 325 User's Handbook
Содержание PC Server 325
Страница 1: ...PC Server 325 User s Handbook IBM...
Страница 6: ...vi PC Server 325 User s Handbook...
Страница 10: ...Laser Compliance Statement x PC Server 325 User s Handbook...
Страница 136: ...Updating the Server Configuration 122 PC Server 325 User s Handbook...
Страница 212: ...Resolving Configuration Conflicts 198 PC Server 325 User s Handbook...
Страница 238: ...Installed Device Records 224 PC Server 325 User s Handbook...
Страница 287: ......
Страница 288: ...IBM Part Number 76H8831 Printed in U S A September 1996 76H8831...