Error code/symptom
FRU/action
00180500
(PCI option ROM checksum
error.)
1.
PCI adapter
2. System board
00180600
(PCI device BIST failure. PCI
bridge error.)
1.
Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
00180700
(PCI device no responding.)
1.
System board
2. PCI adapter
00181000
(General PCI error)
v
Adapter
v
System board
I9990650
(AC power has been restored)
1.
Check cable.
2. Check for interruption of power.
3. Power cable.
POST (ISPR) error procedures
Use the ISPR error procedures to help you solve ServeRAID problems. A complete
list of error codes is listed at “ServeRAID error codes” on page 111.
Note:
Where the ISPR Error Procedures refer to a hard disk drive backplane, see
the chapter of this publication that concerns field replaceable units.
EF10
(Default ISPR)
1. No ISPR error present.
9
ZXX
thru B
ZXX
(SCSI bus error caused by cables, termination, or defective
drives.)
1. Isolate the SCSI subsystem from the controller by disconnecting all hard disk
drive cables from the suspect adapter, and restart the computer.
CAUTION:
Do not press F5. Doing so changes the configuration of the server.
If an ISPR error is still present, perform the following actions until the error is no
longer present:
a. Reseat the controller
b. Replace the controller
Notes:
a. SCSI channel cable details, if any, appear elsewhere in this publication.
b. The adapter/controller detects a configuration change.
Do not
select
Save
Changes
. Instead, press F10 to bypass any options to this effect.
2. If ISPR error is
EF10
after disconnecting cables:
a.
Identify which channel is causing the error by the second digit (Z) of the
original ISPR code as indicated in the following table:
Note:
ServeRAID-4H controllers have four channels; ServeRAID-4L and
-4Lx controllers have only one channel; and ServeRAID-4M and -4Mx
controllers have two channels. ServeRAID-5i controllers have no
channels. The ServeRAID-5i uses the channel connectors of the
integrated SCSI controller of the server.
Symptom-to-FRU index
109
Содержание IntelliStation E Pro
Страница 1: ...IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 2: ......
Страница 3: ...IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 6: ...iv IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 10: ...viii IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 20: ...10 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 138: ...128 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 149: ...Related service information 139...
Страница 150: ...140 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 151: ...Related service information 141...
Страница 152: ...142 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 153: ...Related service information 143...
Страница 154: ...144 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 155: ...Related service information 145...
Страница 156: ...146 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 166: ...156 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 167: ...Related service information 157...
Страница 168: ...158 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 169: ...Related service information 159...
Страница 170: ...160 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 171: ...Related service information 161...
Страница 172: ...162 IBM IntelliStation E Pro Types 6216 and 6226 Hardware Maintenance Manual...
Страница 181: ......
Страница 182: ...Part Number 71P7605 1P P N 71P7605...