NDIS 4.0 (Windows NT) driver messages:
The following error messages are for the NDIS 4.0 drivers.
The explanation and recommended action are included
with each message.
PermaNet(tm) Server: No Secondary Adapter Found. Grouping Mode is
disabled.
Explanation: The failover option requires an adapter that is compatible with
the device driver of the Ethernet controller on the system board. No such
adapter was found.
Action: Make sure the correct adapter is installed.
.
PermaNet(tm) Server: Problem Occurs on the Primary Adapter. Switching
over to the Secondary Adapter.
Explanation: The system detected a problem with the primary Ethernet
connection and has transferred all network traffic to the secondary Ethernet
controller.
Action: Identify the cause of the failure on the primary Ethernet connection.
Restoring the operational state of the primary connection will cause the
network traffic to automatically transfer to the primary Ethernet controller.
PermaNet(tm) Server: Switching back to Primary Adapter.
Explanation: The primary Ethernet connection is now operating correctly.
Network traffic will automatically transfer to the primary Ethernet controller.
Action: None needed, message is for information only.
.
UNIX messages:
The following error messages are
for the SCO UNIX LLI driver.
pnt0-2
PCI search specified, PCI device not found!
Explanation: The driver cannot locate the Ethernet controller on the PCI bus.
Action: Run the NETCONFIG program to search for another Ethernet
controller.
Verify that the PCI Ethernet device type is set to the default (enabled) position
in the Configuration/Setup utility programs (see “PCI bus control” on page 30).
If the problem persists, go to “Diagnostic test programs” on page 10 to run the
diagnostic utility.
pnt0-6
Cannot allocate memory for the adapter during an
interrupt. Please check the Streams parameters.
Explanation: On a SunSoft Solaris system, this message indicates that the
system is out of Streams memory blocks.
Action: Use the CRASH utility to increase the number of Streams memory
blocks.
Modify the interrupt request (IRQ) settings in the Configuration/Setup utility
programs, or run the NETCONFIG program to match the hardware settings.
pnt0-7
Cannot allocate memory for the adapter during reset.
Please check the Streams parameters.
Explanation: The system is out of Streams memory blocks.
Action: Use the CRASH utility to increase the number of Streams memory
blocks.
pnt0-11
Device not found!
Explanation: The driver cannot find an Ethernet controller.
Action: Verify that the PCI Ethernet device type is set to the default
(enabled) position in the Configuration/Setup utility programs (see “PCI bus
control” on page 30). If the Ethernet adapter is enabled, go to “Diagnostic test
programs” on page 10 to run the diagnostic utility.
38
Netfinity Server HMM
Содержание 865951Y - Netfinity 5000 - 51Y
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Страница 195: ...Related service information 187...
Страница 196: ...188 Netfinity Server HMM...
Страница 197: ...Related service information 189...
Страница 198: ...190 Netfinity Server HMM...
Страница 208: ...200 Netfinity Server HMM...
Страница 209: ...Related service information 201...
Страница 219: ......
Страница 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...