PCNTNW-NW-165 The device was not found at IOADDRESS.
Explanation: The Ethernet controller cannot be found at the I/O address
specified.
Action: The Ethernet controller does not require a parameter for the I/O
address. Remove the I/O address parameter.
PCNTNW-NW-167 PCI scan specified, device not found.
Explanation: The driver cannot locate the Ethernet controller on the PCI bus.
Action: Verify that the PCI Ethernet device type is set to the default
(enabled) position in the Configuration/Setup utility programs (see “PCI bus
control” on page 30).
If the problem persists, go to “Diagnostic test programs” on page 10 to run the
diagnostic utility.
PCNTNW-NW-180 The DMA parameter is not necessary for PCI device.
Explanation: The Ethernet controller does not require a DMA setting.
Action: None necessary, message is for information only.
NDIS 2.01 (OS/2) driver messages:
The
following error messages are for the NDIS 2.01 (OS/2)
drivers. The explanation and recommended action are
included with each message.
PCNTND-1
Unable to open the Protocol Manager.
Explanation: The NDIS stack is not configured correctly.
Action: Check and correct the configuration.
PCNTND-6
Out of memory while allocating buffers.
Explanation: The driver could not allocate the requested buffers.
Action: Check the system configuration. Edit the PROTOCOL.INI file to
reduce the number of Txbuffers and Rxbuffers specified for the driver.
PCNTND-7
A Protocol Manager device error occurred.
Explanation: The NDIS stack is not configured correctly.
Action: Check and correct the configuration.
PCNTND-8
Bad status for the Protocol Manager.
Explanation: The NDIS stack is not configured correctly in the
PROTOCOL.INI file.
Action: Check and correct the configuration.
PCNTND-9
Cannot find the PROTOCOL.INI entry.
Explanation: The NDIS stack is not configured correctly in the
PROTOCOL.INI file.
Action: Check and correct the configuration.
PCNTND-10
The Protocol Manager Input Output Control (IOCTL)
failed.
Explanation: The NDIS stack is not configured correctly in the
PROTOCOL.INI file.
Action: Check and correct the configuration.
PCNTND-11
Protocol Manager registration failed.
Explanation: The NDIS stack is not configured correctly.
Action: Check and correct the configuration.
36
Netfinity Server HMM
Содержание 865951Y - Netfinity 5000 - 51Y
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Страница 195: ...Related service information 187...
Страница 196: ...188 Netfinity Server HMM...
Страница 197: ...Related service information 189...
Страница 198: ...190 Netfinity Server HMM...
Страница 208: ...200 Netfinity Server HMM...
Страница 209: ...Related service information 201...
Страница 219: ......
Страница 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...