POST error codes
In the following error codes,
X can be any number or letter.
Error Code/Symptom
FRU/Action
062
(Three consecutive boot
failures using the default
configuration.)
1. Run
Configuration/Setup
2. Battery
3. System Board
101, 102
(System and processor
error)
1. System Board
106
(System and processor
error)
1. System Board
111
(Channel check error)
1. Failing ISA Adapter
2. Memory DIMM
3. System Board
114
(Adapter read-only memory
error)
1. Failing Adapter
2. Run Diagnostics
129
(Internal Cache error)
1. Processor
2. Optional Processor
(if installed)
151
(Real time clock error)
1. Run Diagnostics
2. Battery
3. System Board
161
(Real time clock battery
error)
1. Run
Configuration/Setup
2. Battery
3. System Board
162
(Device Configuration Error)
Important
Be sure to load the
default settings and
any additional desired
settings; then, save
the configuration.
1. Run
Configuration/Setup
2. Battery
3. Failing Device
4. System Board
163
(Real-Time Clock error)
1. Run
Configuration/Setup
2. Battery
3. System Board
164
(Memory configuration
changed)
1. Run
Configuration/Setup
2. DIMM
173
(System CMOS checksum
bad)
1. Run
Configuration/Setup
2. Battery
3. System Board
175
(Hardware error)
1. System Board
160
Netfinity Server HMM
Содержание 865951Y - Netfinity 5000 - 51Y
Страница 2: ......
Страница 8: ...vi Netfinity Server HMM...
Страница 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Страница 195: ...Related service information 187...
Страница 196: ...188 Netfinity Server HMM...
Страница 197: ...Related service information 189...
Страница 198: ...190 Netfinity Server HMM...
Страница 208: ...200 Netfinity Server HMM...
Страница 209: ...Related service information 201...
Страница 219: ......
Страница 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...