Set the ramp time settings for the hoist function to
a value of 0 to 2 seconds in 0.1 second increments.
The setup screen for this submenu is similar to Fig-
ure 66.
TILT FORWARD HYDRAULIC FUNCTION
MAXIMUM SPEED AND RAMP TIMES
To change the ramp up or down time setting or to
adjust the maximum flow supplied for the tilt for-
ward (the hydraulic function 2A settings), follow
the procedure given in Lift Hydraulic Function
Maximum Speed and Ramp Times.
Set the maximum hydraulic flow supplied for the
tilt forward function to a value from 0% to 100%. A
value of 0% deactivates this function.
Set the ramp time settings to a value of 0 to 2 sec-
onds.
The setup screen for this submenu is similar to Fig-
ure 66.
TILT BACKWARD HYDRAULIC FUNCTION
MAXIMUM SPEED AND RAMP TIMES
To change the ramp up or down time setting or to
adjust the maximum flow supplied for the tilt back-
ward (the hydraulic function 2B settings), follow
the procedure given in Lift Hydraulic Function
Maximum Speed and Ramp Times.
Set the maximum hydraulic flow supplied for the
tilt backward function to a value from 0% to 100%.
A value of 0% deactivates this function.
Set the ramp time settings to a value of 0 to 2 sec-
onds.
The setup screen for this submenu is similar to Fig-
ure 66.
AUXILIARY 1A HYDRAULIC FUNCTION
MAXIMUM SPEED AND RAMP TIMES
To change the ramp up or down time setting or to
adjust the maximum flow supplied for hydraulic
function 3A, follow the procedure given in Lift Hy-
draulic Function Maximum Speed and Ramp
Times.
Set the maximum hydraulic flow to a value from
0% to 100%. A value of 0% deactivates this func-
tion.
Set the ramp time settings to a value of 0 to 2 sec-
onds.
The setup screen for this submenu is similar to Fig-
ure 66.
AUXILIARY 1B HYDRAULIC FUNCTION
MAXIMUM SPEED AND RAMP TIMES
To change the ramp up or down time setting or to
adjust the maximum flow supplied for hydraulic
function 3B, follow the procedure given in Lift Hy-
draulic Function Maximum Speed and Ramp
Times.
Set the maximum hydraulic flow to a value from
0% to 100%. A value of 0% deactivates this func-
tion.
Set the ramp time settings to a value of 0 to 2 sec-
onds.
The setup screen for this submenu is similar to Fig-
ure 66.
AUXILIARY 2A HYDRAULIC FUNCTION
MAXIMUM SPEED AND RAMP TIMES
To change the ramp up or down time setting or to
adjust the maximum flow supplied for hydraulic
function 4A, follow the procedure given in Lift Hy-
draulic Function Maximum Speed and Ramp
Times.
Set the maximum hydraulic lift to a value from 0%
to 100%. A value of 0% deactivates this function.
Set the ramp time settings to a value of 0 to 2 sec-
onds.
The setup screen for this submenu is similar to Fig-
ure 66.
2200 SRM 1336
Truck Setup Menu
107
Содержание A1.3-1.5XNT
Страница 6: ... THE QUALITY KEEPERS HYSTER APPROVED PARTS ...
Страница 9: ...Figure 3 Technician Flowchart Sheet 1 of 4 2200 SRM 1336 Menu Flowchart 3 ...
Страница 10: ...Figure 3 Technician Flowchart Sheet 2 of 4 Menu Flowchart 2200 SRM 1336 4 ...
Страница 11: ...Figure 3 Technician Flowchart Sheet 3 of 4 2200 SRM 1336 Menu Flowchart 5 ...
Страница 12: ...Figure 3 Technician Flowchart Sheet 4 of 4 Menu Flowchart 2200 SRM 1336 6 ...
Страница 123: ......
Страница 124: ...TECHNICAL PUBLICATIONS 2200 SRM 1336 2 14 8 13 4 13 12 12 3 12 12 11 ...