• The display does not read 5 bars with a fresh
charged battery. See Step 1 below.
• The display stays at 5 bars as the battery
discharges. See Step 2 below.
• The display reads 0 bars at too high a bat-
tery specific gravity or voltage. See Step 3
below.
• The display reads 0 bars at too low a battery
specific gravity or voltage. See Step 4 below.
Table 22. Battery Setup Factory Defaults
Model
Battery Full
Battery Empty
E2.2-3.5XN (E45-70XN) (A268)
2.12 Volts
1.98 Volts
J2.2-3.5XN (J45-70XN) (A276)
2.10 Volts
2.00 Volts
E1.6-2.0XN (E30-40XN) (A269)
2.12 Volts
1.98 Volts
J1.5-2.0XNT (J30-40XNT) (K160)
2.12 Volts
1.96 Volts
J1.6-2.0XN (J30-40XN) (A935)
2.12 Volts
1.96 Volts
A1.3-1.5XNT (A25-30XNT) (D203)
2.12 Volts
1.96 Volts
J4.0-5.0XN (J80-100XN) (A970)
2.15 Volts
1.96 Volts
E4.0-5.5XN (E80-120XN) (A099)
2.12 Volts
2.00 Volts
1.
If the display does not read 5 bars with a fresh
charged battery the full cell voltage needs to be
lowered. For the BDI to read correctly the truck
must be operated for 10 minutes doing light
driving. If the display still does not read 5 bars
after light driving lower the full cell voltage
0.01V (a change of 0.01V will make a signifi-
cant change) Use the left arrow key to return to
the Operating Screen and drive the truck mo-
mentarily and check to see if the BDI is now at
5 bars. If not lower the full cell voltage another
0.01V, return to the Operating Screen, drive
momentarily and check as above. Repeat as
necessary.
2.
If the display stays at 5 bars as the battery dis-
charges the full cell voltage need to be in-
creased. Run truck until battery is at 75% of
the usable charge as measured per the battery
manufacturer’s instructions (discharged 20% if
80% is usable). If BDI indicator is still at 5 bars
increase the full cell voltage. As above a step of
0.01cell voltage will make a significant change.
Use the left arrow key to return to the Operat-
ing Screen and check to see if there are now 4
bars showing. Repeat as necessary.
NOTE:
The battery must be charged to at leased
50% of its capacity to reset lift lockout
3.
If the display reads 0 bars at too high a battery
specific gravity or voltage operate the truck
checking the battery per the battery manufac-
tures recommendations until the battery is dis-
charged to the manufacturer’s recommenda-
tion. Decrease the empty cell voltage in steps of
0.01 volts. Use the left arrow key to return to
the Operating Screen and check to see if there
are now 1 or more bars showing. Repeat if nec-
essary.
4.
If the display reads 1 or more bars and the bat-
tery is discharged when measured as per the
battery manufacturer’s recommendation. In-
crease the empty cell voltage in steps of 0.01
volts. Use the left arrow key to return to the
Operating Screen and check to see 0 bars are
displayed. Repeat if necessary.
BDI ADJUSTMENT SETTING
NOTE:
This submenu is available to logged in
Service Technicians only.
Figure 52 shows how the Battery Discharge Indica-
tor (BDI) adjustment setting is displayed on the
screen. The Parasitic Current Icon and the present
value are located in the middle of the screen.
Truck Setup Menu
2200 SRM 1336
98
Содержание A1.3-1.5XNT
Страница 6: ... THE QUALITY KEEPERS HYSTER APPROVED PARTS ...
Страница 9: ...Figure 3 Technician Flowchart Sheet 1 of 4 2200 SRM 1336 Menu Flowchart 3 ...
Страница 10: ...Figure 3 Technician Flowchart Sheet 2 of 4 Menu Flowchart 2200 SRM 1336 4 ...
Страница 11: ...Figure 3 Technician Flowchart Sheet 3 of 4 2200 SRM 1336 Menu Flowchart 5 ...
Страница 12: ...Figure 3 Technician Flowchart Sheet 4 of 4 Menu Flowchart 2200 SRM 1336 6 ...
Страница 123: ......
Страница 124: ...TECHNICAL PUBLICATIONS 2200 SRM 1336 2 14 8 13 4 13 12 12 3 12 12 11 ...