TransformerCare Unit
TCU in operation
HYDAC FILTER SYSTEMS GMBH
en
Page 38 / 64
BeWa TCU 3472805b en 2011-07-05.doc
2011-07-05
EDS error messages
If an error is detected a corresponding error message is displayed which must be
acknowledged by pressing any button. Possible error messages are:
Error
Cause
Remedy
E.01
The switchpoints and hystereses
have been set so that the resulting
switch-back point is no longer
within the permissible setting
range.
Example:
The switchpoint is set to 180 bar,
the hysteresis to 200 bar.
Correct the settings.
E.10
A data error has been detected in
the saved settings. Possible
causes include strong
electromagnetic interference or a
defective component.
Check all of the settings
(programming enable,
switchpoints, switch-back points
and basic settings) and correct
these, if necessary.
Contact HYDAC if the error occurs
repeatedly.
E.12
An error has been detected in the
saved calibration data. Possible
causes include strong
electromagnetic interference or a
defective component.
Disconnect the unit from the supply
voltage and then reconnect it.
If the error still occurs, send the
unit to HYDAC to have it
recalibrated or repaired.
E.21
A communication error occurring
within the unit has been detected.
Possible causes include strong
electromagnetic interference or a
defective component.
Disconnect the unit from the supply
voltage and then reconnect it.
Contact HYDAC if the error still
occurs.