background image

Impression Series

®

 

and

 

Impression Plus Series

®

Water Filters

For Models:

• IMBF

• IMBF-MAN

• IMAN

• IMAF-MGS

• IMS

• IMB

• IAG

• IACG-AN

• IMPBF

• IMPBF-MAN

• IMPAF-MGS

• IMPS

• IMPB

• IPAG

• IPACG-AN

Содержание Impression Series

Страница 1: ...Impression Series and Impression Plus Series Water Filters For Models IMBF IMBF MAN IMAN IMAF MGS IMS IMB IAG IACG AN IMPBF IMPBF MAN IMPAF MGS IMPS IMPB IPAG IPACG AN...

Страница 2: ...y this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner contact your...

Страница 3: ...ow Rate Capacity Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing next to scroll through them When stepping through any prog...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...10 feet of piping between its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on t...

Страница 6: ...line flow control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but beca...

Страница 7: ...neration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use of pe...

Страница 8: ...ny number is set allowable range from 1 to 28 a regeneration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override...

Страница 9: ...and holding the regen button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The system is...

Страница 10: ...out salt To initiate a manual regeneration at the next preset regeneration time press and release regen The words REGEN TODAY will flash on the display to indicate that the system will regenerate at t...

Страница 11: ...tank just prior to regeneration this comes in contact with the chlorine pellets dissolves them and is drawn into the filter to disinfect the system periodically We recommend the use of pellets manufac...

Страница 12: ...Pay close attention to media level when filling Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the...

Страница 13: ...stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into thr...

Страница 14: ...tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body ty...

Страница 15: ...on or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGE...

Страница 16: ...conds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not connecte...

Страница 17: ...pression cover 1 CV3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3579WI PC board CC 1 5 CV3110 Drive gear...

Страница 18: ...1 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4...

Страница 19: ...3148 Bypass rotor seal retainer 2 8 CV3152 O ring 135 2 9 CV3155 O ring 112 2 10 CV3156 O ring 214 2 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH46...

Страница 20: ...mbly blue CV3010 1G G injector assembly yellow CV3010 1H H injector assembly green CV3010 1I I injector assembly orange CV3010 1J J injector assembly light blue CV3010 1K K injector assembly light gre...

Страница 21: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Страница 22: ...us positions on the valve is available to aid in assembly or disassembly SERVICE WRENCH CV3193 02 22 CHLORINE TANK ASSEMBLY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH464...

Страница 23: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Страница 24: ...CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut...

Страница 25: ...d Greensand Greensand Amount Cu Ft 1 0 1 5 2 5 Gravel Amount Size No 1 14 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 4 0 4 0 6 0 P...

Страница 26: ...2 0 Calcite 0 5 Calcite 0 75 Calcite 1 0 Gravel Amount Size No 1 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 2...

Страница 27: ...mponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent mann...

Страница 28: ...displays will be shown time of day gallons of treated water available or gallons per minute Pressing next will toggle between the three choices TO SET TIME OF DAY In the event of a prolonged power ou...