Water Conditioner Limited Warranty

Congratulations. You have purchased one of the finest water treatment systems available. In the unlikely 
event of a problem due to defects in material and workmanship, we proudly warrant our water conditioners 
to the original owner, when installed in accordance with Water-Right

®

 specifications. This warranty is 

effective from the date of original installation for:

A period of TEN YEARS: 

 

 Fiberglass mineral tank except for damages due to freezing, 
high pressure (120 PSI and above), extreme temperature  
(100°F and above) or a vacuum on the system. 

A period of FIVE YEARS: 

 

The control valve and all internal components.

     The 

salt 

storage 

container.

A period of ONE YEAR: 

 

All other conditioner components.

Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay 
only freight from our factory and local dealer charges. To obtain local warranty service, contact original dealer 
or an authorized service dealer. If no authorized dealer is located in your area, please ship defective part or 
component freight prepaid to Water-Right, Inc., 1900 Prospect Ct., Appleton, Wisconsin 54914. Water-Right,  
 

at its discretion, will repair or replace the part or component at its expense and return part freight 

collect.

The above provisions of the warranty are valid as long as the unit is connected in compliance with local 
plumbing codes and in an equivalent manner and condition of the original installation and is owned by the 
original owner.
 
This warranty does not cover damages due to accident, fire, flood, freezing, or any other Act of God.  
We are not responsible for damages due to change in water conditions, misapplication, misuse, neglect, 
vacuum, oxidizing agents, alteration, or lack of maintenance. No responsibility is assumed for loss of use 
of the unit, inconvenience, loss or damage to real or personal property or any incidental or consequential 
damages. Furthermore, we assume no liability and extend no warranties, express or implied, for the use 
of this product with a non-potable water source. 

To the extent permitted by law, Water-Right disclaims 

all implied warranties, including without limitation warranties of merchantability and fitness for 
particular purpose; to the extent required by law, any such implied warranties are limited in duration 
to the aforementioned period specified above.

Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty 
lasts. Consequently, the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state    
to state.

Содержание Impression Series

Страница 1: ...Impression Series and Impression Plus Series Water Filters For Models IMBF IMBF MAN IMAN IMAF MGS IMS IMB IAG IACG AN IMPBF IMPBF MAN IMPAF MGS IMPS IMPB IPAG IPACG AN...

Страница 2: ...y this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner contact your...

Страница 3: ...ow Rate Capacity Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing next to scroll through them When stepping through any prog...

Страница 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Страница 5: ...10 feet of piping between its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on t...

Страница 6: ...line flow control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but beca...

Страница 7: ...neration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use of pe...

Страница 8: ...ny number is set allowable range from 1 to 28 a regeneration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override...

Страница 9: ...and holding the regen button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The system is...

Страница 10: ...out salt To initiate a manual regeneration at the next preset regeneration time press and release regen The words REGEN TODAY will flash on the display to indicate that the system will regenerate at t...

Страница 11: ...tank just prior to regeneration this comes in contact with the chlorine pellets dissolves them and is drawn into the filter to disinfect the system periodically We recommend the use of pellets manufac...

Страница 12: ...Pay close attention to media level when filling Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the...

Страница 13: ...stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into thr...

Страница 14: ...tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body ty...

Страница 15: ...on or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGE...

Страница 16: ...conds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not connecte...

Страница 17: ...pression cover 1 CV3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3579WI PC board CC 1 5 CV3110 Drive gear...

Страница 18: ...1 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4...

Страница 19: ...3148 Bypass rotor seal retainer 2 8 CV3152 O ring 135 2 9 CV3155 O ring 112 2 10 CV3156 O ring 214 2 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH46...

Страница 20: ...mbly blue CV3010 1G G injector assembly yellow CV3010 1H H injector assembly green CV3010 1I I injector assembly orange CV3010 1J J injector assembly light blue CV3010 1K K injector assembly light gre...

Страница 21: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Страница 22: ...us positions on the valve is available to aid in assembly or disassembly SERVICE WRENCH CV3193 02 22 CHLORINE TANK ASSEMBLY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH464...

Страница 23: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Страница 24: ...CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut...

Страница 25: ...d Greensand Greensand Amount Cu Ft 1 0 1 5 2 5 Gravel Amount Size No 1 14 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 4 0 4 0 6 0 P...

Страница 26: ...2 0 Calcite 0 5 Calcite 0 75 Calcite 1 0 Gravel Amount Size No 1 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 2...

Страница 27: ...mponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent mann...

Страница 28: ...displays will be shown time of day gallons of treated water available or gallons per minute Pressing next will toggle between the three choices TO SET TIME OF DAY In the event of a prolonged power ou...

Отзывы: