Chapter 4
Diagnostics
41
Code
Description
Problem/Solution
2. If no DIMM has been removed or changed, ensure all DIMMs
are properly inserted in the slots.
3. If the problem persists, one of DIMMs may need to be
replaced. Contact your service representative.
0712
DIMM installation
error
POST has detected an incorrectly installed DIMM or the failure
of one or more DIMMs.
To correct this:
1. If additional memory was just installed in your Netserver,
please verify the installation conforms to the description in
the User's Guide.
2. If this error was reported when no additional memory was just
installed, restart the Netserver.
3. If the error persists, contact your service representative.
0713
Incorrect DIMM
installed
POST has detected one or more DIMMs are not the correct type,
or the correct speed.
To correct this:
1. If additional memory was just installed in your Netserver,
please verify the correct DIMM type and speed for this
Netserver was installed. Refer to the DIMM description in the
User's Guide.
2. If this error was reported and no additional memory was just
installed, restart the Netserver.
3. If the error persists, contact your service representative.
0800
Cache memory size
error
POST has detected the cache memory size is smaller than
previously detected.
To correct this:
1. If the processor has just been replaced, press
[F4]
to
automatically validate the change.
2. If the problem persists, the processor may need to be
replaced.
0801
Cache boot error
POST has detected an error in the cache memory module.
To correct this:
1. Verify the processor is installed correctly.
2. If the problem persists, the processor may need to be
replaced. Contact your service representative.
0900
Integrated LAN
disable error
The system could not disable the integrated LAN.
To correct this: