Figure 54 Configuration > Save/Restore page
IMPORTANT:
When the defaults are restored, the library will rediscover and renumber the
tape drives from the bottom of the library up. If a tape drive was added between two other tape
drives since the last time the drives were discovered, that tape drive and the ones above it will
be renumbered. You might need to update the configuration of the backup application when tape
drives are renumbered.
To save the device configuration to a file, click
Save
and follow the instructions on the RMI to
specify a file location.
To restore the device configuration from a file, browse to the location of the saved configuration
file and click
Restore
.
NOTE:
For security reasons, the system configuration cannot be restored from a file or restored
to the factory defaults when encryption is enabled. Disable encryption from the
Configuration
> Security
screen before restoring the system configuration from a file or from the factory defaults.
Operations
Moving media
Use the
Operations > Move Media page
to move tape cartridges within the device.
IMPORTANT:
Moving media manually can interfere with backup software operations. Ensure
backups are complete before moving media.
Using the RMI