Table 31 Main error codes (continued)
Details and solution
Description
Error code
Drive logged out
FB
•
Update the tape drive firmware to the current
version.
Internal SCSI command failed with check
condition
FC
•
Try the operation again.
•
If the error occurs again contact Hewlett
Packard Enterprise customer support.
Internal SCSI command timeout
FD
1
Gripper: The part of the robotics assembly that pinches media in order to grip it.
2
Slider: The part of the robotics assembly that plunges in and out for
get
and
put
operations.
3
Elevator: The part of the robotics assembly that moves in the vertical direction.
4
Rotation: The part of the robotics assembly that turns the robot to face each magazine and the
drive.
5
Sled: The part of the robotics assembly that moves the robot towards the OCP or back towards
the drive.
Error sub-code descriptions
Table 32 Robotic error sub-codes
Description
Sub-code
Mechanical initialization failure
01
Connection to slave robotic failed
02
Error motor initialization
03
Error during gripper
1
close
04
Error slider
2
home positioning
05
Error elevator
3
home movement
06
Error during sled
5
movement to rotation
4
position
07
Error during rotation
4
initialization, get range failed
08
Error elevator
3
init
09
Error during rotation
4
to far position
0A
Error first sled
5
init, move to sensor failed
0B
Error during sled
5
movement to rotation
4
position
0C
Error during rotation
4
to slide position
0D
Error slider
2
init, get range failed
0E
Error during slider
2
forward movement
0F
Error gripper
1
init, get range failed
10
Error during slider
2
home movement
11
Error during rotation
4
to FAR position
12
Error sled
5
init, move to sensor failed
13
Error during sled move — check shipping lock
14
Error inventory scan
20
166
Troubleshooting