Table 31 Main error codes (continued)
Details and solution
Description
Error code
magazine was replaced with a one-slot mailslot
magazine.
Note: You will need to reconfigure your
backup software.
•
If the issue continues, inspect the magazine
for damage and missing light pipes or
magazine prism pieces (clear plastic pieces
in each slot).
•
Retry the backup with a token with space for
more keys.
NOTE:
Each token can hold 100 keys.
Keys cannot be overwritten or deleted; only
unique keys will be written to the token.
Key server token backup not successful (not
enough available space on target token)
E1
•
Update the library firmware to the current
version.
Unsupported hardware detected. Some
hardware that is connected to the library requires
updated library firmware.
E2
Error during key server token backup; backup
process unsuccessful.
E3
•
Retry the backup with a different token.
•
If the error occurs again, contact Hewlett
Packard Enterprise customer support.
Drive firmware does not support encryption.
E4
•
Ensure that all tape drives that support
encryption (LTO-4 and later generations) are
at the minimum firmware required for the
Encryption Kit:
◦
Ultrium 1760 SCSI: W22W
◦
Ultrium 1760 SAS: U26W
◦
Ultrium 1840 SCSI: B45W
◦
Ultrium 1840 SAS: H44W
•
If necessary, update the tape drive firmware
to the current version.
•
When encryption is enabled with the
Encryption Kit, ensure that all tape drives in
the logical library support encryption (LTO-4
and later generations). When possible, avoid
including LTO-2 and LTO-3 tape drives in a
logical library when encryption is enabled.
Drive generation does not support encryption.
E5
Key Server Token restore process did not
complete, Key Server Token restore failed.
E6
•
Retry the operation on the same key server
token.
•
Retry the operation on a new key server
token.
Incorrect Key Server Toke Type. Token not
supported within this device.
E7
•
Verify that the USB device is an HPE key
server token from the 1/8 G2 & MSL
Encryption Kit.
•
Verify that the USB device is a key server
token from the Encryption Kit.
•
Retry the operation on a new key server
token.
Encryption Kit not available due to incompatible
library controller.
E8
Error codes
163