Turn the Delay knob and notice that its value is displayed in the status line.
The Delay knob moves the main sweep horizontally, and it pauses at
0.00 s, mimicking a mechanical detent. At the top of the graticule is a
solid triangle (
▼
) symbol and an open triangle
(
∇
) symbol. The
▼
symbol indicates the trigger point and it moves
in conjunction with the Delay knob. The
∇
symbol indicates the time
reference point. If the time reference softkey is set to left, the
∇
is
located one graticule in from the left side of the display. If the time
reference softkey is set to center, the
∇
is located at the center of the
display. The delay number tells you how far the reference point
∇
is
located from the trigger point
▼
.
All events displayed left of the trigger point
▼
happened before the
trigger occurred, and these events are called pretrigger information.
You will find this feature very useful because you can now see the
events that led up to the trigger point. Everything to the right of the
trigger point
▼
is called posttrigger information. The amount of delay
range (pretrigger and posttrigger information) available is dependent
on the sweep speed selected. See "Horizontal System" in chapter 5 for
more details.
The Oscilloscope at a Glance
To set up the time base
1–13
Содержание HP 54600B
Страница 7: ...vi ...
Страница 12: ...1 The Oscilloscope at a Glance ...
Страница 16: ...Softkey Menu Reference Press this key To obtain this menu Figure 1 4 To obtain this menu Press this key 1 5 ...
Страница 28: ...2 Operating Your Oscilloscope ...
Страница 69: ...2 42 ...
Страница 70: ...3 Using Option 005 Enhanced TV Video Trigger HP 54602B ...
Страница 148: ...Exploded view of oscilloscope Figure 4 11 Service Replacing Parts in the Oscilloscope 4 59 ...
Страница 151: ...Exploded view of Option 005 and related oscilloscope parts Figure 4 12 Service Replacing Parts in the Oscilloscope 4 62 ...
Страница 153: ...4 64 ...
Страница 154: ...5 Performance Characteristics ...
Страница 175: ...Glossary 8 ...