Measure the power supply voltages at L1, L2, and L3 on the system
board.
The test points are not marked on the system board; see figure below for
location of test points.
Make sure that the voltage measurements are within the following tolerances.
Table 4-13
Power Supply Voltage Tolerances
+
5.1 V
±
150 mV (
+
4.95 V to
+
5.25 V)
+
15.75 V
±
787 mV (
+
14.96 V to
+
16.54 V)
−
15.75 V
±
787 mV (
−
14.96 V to
−
16.54 V)
Low Voltage Power Supply voltage test points
(bottom side of oscilloscope
Figure 4–1
Service
Adjusting the Oscilloscope
4–29