175
Default level
2: System level
Parameters
None
Examples
# Enable CSPF.
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te cspf
mpls te cspf timer failed-link
Description
Use the
mpls te cspf timer failed-link
command to configure the failed link timer.
Use the
undo mpls te cspf timer failed-link
command to restore the default.
Related commands:
mpls te cspf
.
Syntax
mpls te cspf timer failed-link
timer-interval
undo mpls te cspf timer failed-link
View
MPLS view
Default level
2: System level
Parameters
timer-interval
: Specifies the failed link timer setting, ranging from 0 to 300 seconds. The default is 10
seconds.
Examples
# Set the failed link timer to 50 seconds.
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te cspf timer failed-link 50
mpls te failure-action teardown
Description
Use the
mpls te failure-action teardown
command to enable the capability of tearing down a failed RSVP
TE tunnel and then re-establishing it.
Use the
undo
mpls te failure-action teardown
command to disable the capability.
By default, this capability is disabled.