3-234
Performance Tests
ETSI/ANSI Receiver Monitor Levels (Option 110)
Procedure
1. Recall the HP 37717C DEFAULT SETTINGS as shown on 3-2.
2. Connect the equipment as shown in Figure 3-66.
Figure 3-66
Option 110 Receiver Monitor Input
Fixed Attenuator (Qty 2)
: HP 8491A Option 006 (6dB; 50
Ω
)
Fixed Attenuator (Qty 2)
: HP 8491A Option 003 (3dB; 50
Ω
)
Matching Pad 75/50
Ω
(7.6dB loss)
: HP 11852B
Matching Pad 50/75
Ω
(4.2dB loss)
: HP 11852B
Table3- 10