3-6
Performance Tests
PDH Internal Transmitter Clocks (Options UKK, [USB], UKJ, [USA])
PDH Internal Transmitter Clocks (Options UKK, [USB],
UKJ, [USA])
Specifications
Description
This test verifies that the PDH transmit data rates are within limits. These limits
assume the instrument is within the annual calibration cycle. The Frequency Offset
capability (deviation from Standard Bit Rate) is also tested here.
The test uses a Frequency Counter connected to the PDH Signal Out port to measure
the data rate on an "all ones" pattern. This gives an indirect measure of the internal
transmitter clock frequency as the data is clocked by the internal clock oscillator.
Because the Frequency Counter triggers from the positive pulses only, the frequency
count will be half the selected data rate.
Equipment Required
Bit Rate
Option
Specification
139.264 MHz
UKJ, [USA], UKK, [USB]
139.264 MHz
±
626.28 Hz
34.368 MHz
UKJ, [USA], UKK, [USB]
34.368 MHz
±
154.66 Hz
8.448 MHz
UKJ, [USA], UKK, [USB]
8.448 MHz
±
38.0 Hz
2.048 MHz
UKJ, [USA], UKK, [USB]
2.048 MHz
±
9.22 Hz
704 kHz
UKK, [USB]
704 kHz
±
3.17 Hz
Frequency Counter
: HP 5335A Option 010
75
Ω
Termination
: HP 15522-80010
T Connector
: HP 1250-0781
Содержание 37717C
Страница 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Страница 5: ...2 ...
Страница 21: ...xviii Contents ...
Страница 102: ...2 13 Installation Connecting to the Network Location of Laser Apertures on Options 130 and 131 ...
Страница 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Страница 125: ...3 16 Performance Tests PDH Transmitter Output UKK USB UKJ USA Figure 3 7 8 Mb s Isolated Negative Pulse ...
Страница 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Страница 375: ...3 266 Performance Tests Performance Test Record ...
Страница 379: ...4 4 Installation Current Previous Terminology ...
Страница 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Страница 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...