3-85
Performance Tests
STM-1 Transmitter Output Waveshape (Options US1, [US5], A1T, [A1U],
A3R [A3S], 120)
STM-1 Transmitter Output Waveshape (Options US1,
[US5], A1T, [A1U], A3R [A3S], 120)
Specifications
Description
An oscilloscope is connected to the HP 37717C Transmitter STM-1 output and used
to view the waveforms with All Ones and All Zeros patterns selected in turn. The
displayed waveshape is checked against the relevant ITU G.703 mask. The STM-1
Framing is disabled during this test using the
function of the HP
37717C.
Equipment Required
Procedure
CMI All Ones Waveshape
1. Connect up the equipment as shown in Figure 3-34 and recall HP 37717C
DEFAULT SETTINGS as shown on 3-2.
Figure 3-34
STM-1 Transmitter Output Waveshape Test Setup
Meets ITU Recommendation G.703
MODULE DEBUG
Oscilloscope
: HP 54503A
ThinkJet Printer
: HP 2225A
75
Ω
Termination
: HP 15522-80010
T Connector
: HP 1250-0781
Содержание 37717C
Страница 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Страница 5: ...2 ...
Страница 21: ...xviii Contents ...
Страница 102: ...2 13 Installation Connecting to the Network Location of Laser Apertures on Options 130 and 131 ...
Страница 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Страница 125: ...3 16 Performance Tests PDH Transmitter Output UKK USB UKJ USA Figure 3 7 8 Mb s Isolated Negative Pulse ...
Страница 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Страница 375: ...3 266 Performance Tests Performance Test Record ...
Страница 379: ...4 4 Installation Current Previous Terminology ...
Страница 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Страница 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...