3-159
Performance Tests
Wander/Slips Measurement (Options UHN, [US9], A1M [A1Q], A1N
[A1R], A1P [A1S], A3L [A3M], A3V [A3W], A3N [A3P])
Jitter Receiver STM-1E Input Equalization (Options
A1M [A1Q], A1N [A1R], A1P [A1S], A3L [A3M], A3V
[A3W], A3N [A3P])
N OT E
An SDH Module must be fitted for this test - see Appendix B.
Specification
Description
STM-1E Jitter Receiver Equalization is verified by inserting the special Cable
between the STM-1 OUT port on the SDH Module and the STM-1 IN port on the
Jitter Receiver Module and checking for error-free operation.
Equipment Required
Procedure
1. Recall the HP 37717C DEFAULT SETTINGS as shown on 3-2.
2. Select TRANSMITTER OUTPUT [SDH] and RECEIVER INPUT [SDH
JITTER].
3. Connect the STM-1 OUT port on the SDH Module to the STM-1 JITTER IN port
on the Jitter Receiver Module, via the Cable Attenuator.
4. Verify that all the front panel Alarm leds are off.
5. Press
and check that the display
indicates NO TROUBLE.
6. Press
to halt the measurement.
7. Disconnect all the test equipment.
Receiver Equalization
Automatic for cable loss up to 12dB at half the bit rate.
Cable Attenuator (70 m)
: HP 8120-0049
RESULTS
TROUBLE SCAN
RUN/STOP
RUN/STOP
Содержание 37717C
Страница 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Страница 5: ...2 ...
Страница 21: ...xviii Contents ...
Страница 102: ...2 13 Installation Connecting to the Network Location of Laser Apertures on Options 130 and 131 ...
Страница 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Страница 125: ...3 16 Performance Tests PDH Transmitter Output UKK USB UKJ USA Figure 3 7 8 Mb s Isolated Negative Pulse ...
Страница 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Страница 375: ...3 266 Performance Tests Performance Test Record ...
Страница 379: ...4 4 Installation Current Previous Terminology ...
Страница 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Страница 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...