3-44
Performance Tests
PDH Receiver Equalization (Options UKK, [USB], UKJ, [USA], UKL,
[USC], UKN, [USE])
Procedure
1. Recall the HP 37717C DEFAULT SETTINGS as shown on 3-2.
2. Connect up the equipment as shown in Figure 3-21.
3. Set the oscilloscope: TERMINATION - 1 M
Ω
PROBE - 1:1
Figure 3-21
PDH Receiver Equalization Test Setup
704 kb/s
N OT E
Steps 4 to 8 are only valid if Option UKK, [USB] is fitted.
4. Press
and set up the display
as shown opposite.
5. Select
TEST TIMING [SINGLE] [5 SECS]
RECEIVE
RESULTS
TIMING CONTROL