
3-95
Performance Tests
STM-1 Receiver Monitor Input (Special Option 808)
STM-1 Receiver Monitor Input (Special Option 808)
Specification
Description
A fixed attenuator and a special cable attenuator are inserted between the STM-1
OUT port and the STM-1 IN port. The Receiver monitor mode is verified by
attenuating the signal by 20dB, along with the cable attenuator, and checking for
error-free operation.
Equipment Required
Procedure
1. Recall the HP 37717C DEFAULT SETTINGS as shown on 3-2.
2. Select TRANSMITTER OUTPUT [SDH] and RECEIVER INPUT [SDH].
3. Connect up the equipment as shown in Figure 3-43.
Receiver Monitor Mode
20 dB of flat gain
6dB Equalization at 1/2 Bit Rate
3 dB Attenuator (N-type)
: HP 8491A Option 003
6 dB Attenuator (N-type)
: HP 8491A Option 006
75/50
Ω
Matching Pad (N-type)
: HP 11852B (Qty 2)
N-type (f) to BNC (f) Adaptor
: HP 1250-1536 (Qty 2)
N-type (m) to N-type (f)Adaptor
: HP 1250-1475
Cable Attenuator (35m)
: HP 8120-0049
Содержание 37717C
Страница 2: ...HP 37717C Communications Performance Analyzer Calibration Manual ...
Страница 5: ...2 ...
Страница 21: ...xviii Contents ...
Страница 102: ...2 13 Installation Connecting to the Network Location of Laser Apertures on Options 130 and 131 ...
Страница 109: ...2 20 Installation Additional Precautions for Service Engineers ...
Страница 125: ...3 16 Performance Tests PDH Transmitter Output UKK USB UKJ USA Figure 3 7 8 Mb s Isolated Negative Pulse ...
Страница 312: ...3 203 Performance Tests Trigger Output Option UKZ Figure 3 57 Monitor Input Test Setup ...
Страница 375: ...3 266 Performance Tests Performance Test Record ...
Страница 379: ...4 4 Installation Current Previous Terminology ...
Страница 392: ...B 9 Appendix B Fitting Calibrating Testing New Modules Typical Jitter Transmit Spectrum ...
Страница 393: ...B 10 Appendix B Fitting Calibrating Testing New Modules ...