7
107035-02 EN FR26 ROW 0499 Printed in Germany
APPLICATION EXAMPLES
FIG 9. DUAL CHANNEL EMERGENCY STOP CIRCUITRY
(WITH CROSS-FAULT MONITORING )
23
31
24
32
Honeywell
FF-SRS 5925
(A)
Start
Emer-
gency
stop
(B)
Machine
Control
S1 Cross fault detection
manual
with
automatic
Factory Setting
Position of internal
switch S2 (Start mode):
see note
(A)
S2 Start mode
24Vdc/ac
0V
Fuse
Fuses
Power
This circuit has redundancy in the emergency-stop control circuit and therefore offers the highest possible
safety level.
FUNCTIONAL DESCRIPTION:
Manual start mode:
1. After removing the stop condition, press and release the START push button to restart the safety control module.
2. The K1 and K2 LED’s will turn ON indicating that the safety relays K1 and K2 are energized. The two normally open
safety contacts will close and the normally closed safety contact will open allowing the machine to operate.
Automatic start mode:
1. After removing the stop condition, the safety control module will immediately reset.
2. The K1 and K2 LED’s will turn ON indicating that the safety relays K1 and K2 are energized. The two normally
open safety contacts will close and the normally closed safety contact will open allowing the machine to operate.
APPLICATION NOTES:
Note (A): Manual start mode: Insert start push-button and select internal switch S2 as illustrated above
Automatic start mode: Insert jumper and select internal switch S2 to automatic start mode
Note (B): Dual channel safety devices: This may be an emergency stop push button in series with dual output
safety switching devices (OSSD) such as
- safety light curtains (FF-SB, FF-LS), single beam (FF-SPS4), modular safety light curtains (FF-SCAN),
- safety mats (FF-SM),
- safety laser scanner (FF-SE),
- dual output safety limit or interlock switches (for example: CLS, GK and GSS).
IMPROPER AUTOMATIC START MODE IN PERIMETER GUARDING APPLICATIONS
•
If the module is in the automatic start mode, another part of the safety control circuitry must keep the
latched function engaged.
Failure to comply with these instructions could result in death or serious injury.
Содержание SYA14 Series
Страница 2: ...2 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 6: ...6 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 26: ...26 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 62: ...62 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 70: ...70 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 76: ...76 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 78: ...78 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 79: ...107031 23 EN FR26 GLO 1199 Printed in France 79 8 CE Declaration of Conformity ...
Страница 80: ...80 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 84: ......
Страница 158: ......
Страница 160: ......
Страница 161: ...For application help call 1 800 537 6945 Honeywell MICRO SWITCH Sensing and Control 80 ...
Страница 165: ...3 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 201: ...39 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 205: ...43 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 207: ...45 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 208: ...107022 14 EN FR26 GLO 0100 Printed in Germany 46 9 Declaration of Conformity ...
Страница 219: ...11 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Страница 229: ...21 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Страница 257: ...49 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Страница 260: ...107006 11 EN FR26 GLO 0300 Printed in Germany 52 9 3 Declaration of conformity ...
Страница 263: ...PK 107007 1 EN FR26 GLO 298 Printed in France Safety Mat Installation Manual FF SM Series Safety Mat PK 107007 Issue 1 ...
Страница 264: ...ii Honeywell PK 107007 01 EN FR26 GLO 0298 Printed in France For application help see Warranty Information ...
Страница 340: ...Safety Perimeter Guarding Installation Manual FF SPS4 Series Safety Perimeter Guarding ...
Страница 536: ...2 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 538: ...4 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 542: ...107004 15 EN FR26 ROW 0899 Printed in France 8 This page has been left intentionally blank ...
Страница 620: ...86 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 624: ...90 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 626: ...92 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 627: ...107004 15 EN FR26 ROW 0899 Printed in France 93 8 CE Declaration of Conformity ...
Страница 628: ...94 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...