IMPROPER ELECTRICAL INSTALLATION
•
Each safety mat activation must stop dangerous machine operation within the response time of the
components.
•
Clearing the sensing zone must not start dangerous machine operation. When restarting machine
operation, a normal machine control start sequence must be used.
•
If electrical power is removed from a machine, its restoration must not initiate dangerous machine
operation; a normal machine control start sequence must be used.
•
If a safety mat system is activated, the machine must NOT be able to restart.
•
The external safety relays located between the safety outputs and the machine control circuitry must
be monitored.
•
In the event of component failure, the machine control circuitry must stop dangerous machine
operation and prevent the next machine cycle activation.
•
A Programmable Logic Controller must NOT be able to override a manual restart function.
•
As the control unit operates in a automatic restart mode, another part of the safety control circuitry
must keep the latched function engaged.
•
To keep the latched function engaged and maintain control reliability, use safety components only.
Do not use a programmable logic controller (PLC).
•
Strictly adhere to all electrical connection instructions and local wiring standards.
Failure to comply with these instructions could result in death or serious injury.
Maintenance
POWER APPLIED TO MACHINE CONTROL SYSTEM
Turn off and disconnect power from FF-SM Series safety mat/control unit and machine.
Failure to comply with these instructions could result in death or serious injury.
Fuse Replacement
The control unit is equipped with an emitting and receiving circuit board. Each circuit board is
protected by a power supply fuse. These power supply fuses are rated to protect the
equipment against high over voltage. See figure 4-1 for fuse F1 and F2 locations.
Figure 4-1 Fuse Locations
(1)
O
N
12
1
2
3
+
-
A1
A2
B1
C1
B2
C2
C4 B3
Test
F1
F2
A4 A5
N(+) P(-)
Cable Drum
Replace fuse as follows:
1. Remove power from safety mat system.
2. Replace blown fuse with new fuse (see order guide).
3. Perform the operational test and inspection to ensure proper functional readiness.
Fuse F2
Fuse F1
Содержание SYA14 Series
Страница 2: ...2 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 6: ...6 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 26: ...26 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 62: ...62 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 70: ...70 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 76: ...76 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 78: ...78 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 79: ...107031 23 EN FR26 GLO 1199 Printed in France 79 8 CE Declaration of Conformity ...
Страница 80: ...80 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Страница 84: ......
Страница 158: ......
Страница 160: ......
Страница 161: ...For application help call 1 800 537 6945 Honeywell MICRO SWITCH Sensing and Control 80 ...
Страница 165: ...3 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 201: ...39 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 205: ...43 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 207: ...45 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Страница 208: ...107022 14 EN FR26 GLO 0100 Printed in Germany 46 9 Declaration of Conformity ...
Страница 219: ...11 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Страница 229: ...21 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Страница 257: ...49 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Страница 260: ...107006 11 EN FR26 GLO 0300 Printed in Germany 52 9 3 Declaration of conformity ...
Страница 263: ...PK 107007 1 EN FR26 GLO 298 Printed in France Safety Mat Installation Manual FF SM Series Safety Mat PK 107007 Issue 1 ...
Страница 264: ...ii Honeywell PK 107007 01 EN FR26 GLO 0298 Printed in France For application help see Warranty Information ...
Страница 340: ...Safety Perimeter Guarding Installation Manual FF SPS4 Series Safety Perimeter Guarding ...
Страница 536: ...2 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 538: ...4 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 542: ...107004 15 EN FR26 ROW 0899 Printed in France 8 This page has been left intentionally blank ...
Страница 620: ...86 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 624: ...90 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 626: ...92 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Страница 627: ...107004 15 EN FR26 ROW 0899 Printed in France 93 8 CE Declaration of Conformity ...
Страница 628: ...94 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...