7.3.7.4 Average Temperature & Water Level Measurement
7.3.7.4.1 Introduction
The Field Interface Instrument - VITO1 (FII-VT) board is a VITO-data
processor module, which calculates average product- and Vapour
temperatures, and optionally a water level
Figure 7-16
The FII-VT board with its planar transformer
By using the HART
®
protocol, the FII-VT module can be connected to
one VITO-interface which in turn is connected to a probe for
product
temperature
,
Vapour temperature
,
water level
, or a combination of
these.
The FII-VT board has a planar transformer for galvanic isolation from
the HART bus. See
Figure 7-16
.
LED LE1 is the board’s
[Health]
LED. LEDs LE2 and LE3 will be flashing
to indicate activity on the HART bus. LE2 indicates data is being
transmitted (Tx), LE3 indicates data is being received (Rx).