COMMISSIONING
168
Service Manual
Part No.: 4417340 Revision 1
954 SmartServo FlexLine
This setting is used for host systems that cannot switch directly from
sending to receiving
.
The delay time can be set between
0
and 200
0
msec
.
On the TAB sheet
GPU-slave
communication parameters can be set
such as: GPU and FlexConn interface addresses
,
parity and modem
control type (Refer to Figure "HCM-GPU Slave").
Figure 7-30
HCM-GPU Slave
Identification:
An 8 character long name for the HCM-GPU board.
GPU interface address:
The address of the SmartLink, ranging from 0 till 9 (similar as the CIU
address). Each SmartLink, connected to the same PC ComPort, must
have a unique address. If the GPU interface address is changed from
default, and the new address has been sent to the HCM-GPU module,
then also change the address at the SmartLink icon Properties TAB
sheet (one level higher).