COMMISSIONING
Part No.: 4417340 Revision 1
Service Manual
245
954 SmartServo FlexLine
The same procedure must be followed for all different levels, with for
instance an interval of 1 meter. Then the following table is obtained:
Example of hydrostatic deformation figures
Level
[m]
Deformation
[mm]
Level
[m]
Deformation
[mm]
Level
[m]
Deformation
[mm]
0
0
8
0.54
16
2.64
1
0.01
9
0.69
17
3.08
2
0.03
10
0.88
18
3.57
3
0.07
11
1.09
19
4.17
4
0.13
12
1.32
20
4.71
5
0.20
13
1.59
21
5.36
6
0.29
14
1.90
21.945
6.04
7
0.40
15
2.25
The values in this table are the basis for the graph in
Figure 7-43
Figure 7-43
Example of hydrostatic deformation correction
Calculate a regression line from the level where the tank shell
deviation is approximately 0.5 mm. In this example, the regression line
is calculated from 8 meters level till the maximum level.
Then, the [Hydrostatic deformation factor] becomes: 0.3869 mm/m.
The [Hydrostatic deformation level] is the point where the regression
line crosses the X-axis; in this example at 8.1435 m.
Protection and detection settings
For proper functioning the servo gauge has several protection
mechanisms implemented. For normal operation these protection
Содержание FlexLine SmartServo 954
Страница 1: ...Service Manual 954 SmartServo FlexLine ...
Страница 197: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 189 954 SmartServo FlexLine ...
Страница 202: ...COMMISSIONING 194 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 203: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 195 954 SmartServo FlexLine ...
Страница 300: ...APPENDIX A 292 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 302: ...APPENDIX B 294 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...