TROUBLE SHOOTING
288
Service Manual
Part No.: 4417340 Revision 1
954 SmartServo FlexLine
Status code
(SmartView)
Description
(Engauge)
Remarks
6162
Drum slip occurred
Probable slip of the inner and outer
magnet. This can only be resolved by
entering and exiting maintenance mode.
Please check displacer level before
continuing, there might be an offset of
(multiples of) 11 cm. Refer to sections
7.7.3
and
11.1
.
6164
Resetting frequency sensor
Frequency sensor failed to start-up but
is recovering. Please wait a short while.
6170
Wire rupture
Please check the wire and displacer.
Refer to section
7.7.3
.
6172
SAT displacer weight out of
range
SAT failure (refer to section
8.7
). Please
check the [SAT raise height up] or check
the displacer weight in air (refer to
sections
9.1.2
and
9.1.3.
)
6174
SAT frequency difference too
large
SAT failure (refer to section
8.7
). Please
check the bearings (refer to sections
9.1.1
and
9.1.3
).
6176
SAT displacer immersed weight
out of range
SAT failure (refer to section
8.7
). The
displacer weighs too much in the
product. Please check the [SAT raise
height down].
6178
SAT displacer stuck
SAT failure (refer to section
8.7
). The
displacer is not able to move freely.
6182
Frequency out of range
Sensor frequency larger than 25 kHz.
Please check the frequency sensor if
this error is persistent.
6183
Invalid drum circumference
Commissioning error (refer to section
7.4
).
6184
Unable to get data from novram
6185
Motor limit high range exceeded
The displacer is above the motor limit
high position. Move the displacer down
(refer to chapter
11.1
) or adjust the
motor position limits.
Note: please check if the drum
circumference is set to a correct value
(should be approximately 340 mm).
6186
Motor limit low range exceeded
The displacer is below the motor limit
low position. Move the displacer up
(refer to chapter
11.1
) or adjust the
motor position limits.
Note: please check if the drum
circumference is set to a correct value
(should be approximately 340 mm).
6187
Motor exit data crc corrupted
6188
Motor limits high and low
distance too small
Commissioning error. The motor limits
are too close to each other. The
distance needs to be at least 25 mm.
Содержание FlexLine SmartServo 954
Страница 1: ...Service Manual 954 SmartServo FlexLine ...
Страница 197: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 189 954 SmartServo FlexLine ...
Страница 202: ...COMMISSIONING 194 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 203: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 195 954 SmartServo FlexLine ...
Страница 300: ...APPENDIX A 292 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 302: ...APPENDIX B 294 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...