COMMISSIONING
130
Service Manual
Part No.: 4417340 Revision 1
954 SmartServo FlexLine
• MRT (see
Figure 7-20
)
Name
Explanation
Value Range
Default
[Element type]
See TABLE below.
3 characters
<RCB>
<RCN>
<RCS>
<QCB>
<QCN>
<QCS>
<--->
[Number of elements]
The number of elements
(resistors) an MRT probe
has
<1 .. 14>
<0>
[Lowest element offset]
The distance from tank zero
till the lowest position of the
MRT probe
floating point number:
<-x.x .. +x.x>
<80.0>
[MRT element length] if MRT
length table = <T>
The lengths of the MRTs
including anchor eye
14 floating point numbers:
<-x.x .. +x.x>
<0,0,0,0,0,0,0,0,0,0,0,0,0,0>
[MRT length table]
Specifies whether a fixed
range of MRT resistors is
used (=
<F>
) or user-
configured lengths (=
<T>
).
Fixed lengths are:
0.25 / 0.65 / 1.25 / 1.95 /
2.85 / 4.15 / 5.65 / 7.35 /
9.25 / 11.65 / 14.65 /
18.45 / 22.95 / 29.65
1 character
<F>
<T>
<F>
R..
= an MRT
without
spot element
Q..
= an MRT
with
spot element
.CB
Rth = 90.2935 + T x 0.38826 (- 100 t 280 °C)
.CN
Rth = 90.4778 + T x 0.38090 (- 100 t 280 °C)
.CS
Rth = 90.5000 + T x 0.38730 (- 100 t 280 °C)
Table 7-7
Element type definitions
Содержание FlexLine SmartServo 954
Страница 1: ...Service Manual 954 SmartServo FlexLine ...
Страница 197: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 189 954 SmartServo FlexLine ...
Страница 202: ...COMMISSIONING 194 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 203: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 195 954 SmartServo FlexLine ...
Страница 300: ...APPENDIX A 292 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 302: ...APPENDIX B 294 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...