7.3.4.12 Advanced Configuration
Name
Value Range
Default Value
Explanation
[Displacer area]
<0.0065>
The displacer area must be
entered at the point where
the displacer touches the
interface when the control
loop is in balance.
[Integration time 1]
[Integration time 2]
[Integration time 3]
<2>
<2>
<2>
Used to filter out (fast)
fluctuations of the resp.
interfaces 1, 2 and 3.
[Wire weight per
unit of length]
<0.00025>
This entity is used to
compensate the set point
with the weight of the wire.
[Wire temperature
coefficient]
<1.2E-05>
Determines the temperature
expansion coefficient of the
wire (according to a related
table)
[Wire cross
sectional area]
<3.1416E-08>
Determines the cross
sectional area of the wire.
[Elasticity
coefficient]
<2E+11>
Determines the elasticity
coefficient of the wire
(according to a related table)
Drum blind length
<0.0>
Determines the non used
part of the wire on the drum
when the wire length > 50m
till 150m. concerning related
calculations.
Содержание FlexLine SmartServo 954
Страница 1: ...Service Manual 954 SmartServo FlexLine ...
Страница 197: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 189 954 SmartServo FlexLine ...
Страница 202: ...COMMISSIONING 194 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 203: ...COMMISSIONING Part No 4417340 Revision 1 Service Manual 195 954 SmartServo FlexLine ...
Страница 300: ...APPENDIX A 292 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...
Страница 302: ...APPENDIX B 294 Service Manual Part No 4417340 Revision 1 954 SmartServo FlexLine ...