- 0 -
HLP-C
+
Inverters
D. Function description of High, intermediate and low
terminals
:
RUN
SPL
Terminal
SPM
Terminal
SPH
Terminal
Result
ON
OFF
OFF
OFF
Mai n f requency a nd
frequency run with the
set value of C000.
ON
ON
OFF
OFF
Low speed and
frequency run with the
set value of C035.
ON
ON/OFF
ON
OFF
Intermediate speed and
frequency run with the
set value of C036.
ON
ON/OFF ON/OFF
ON
High speed and
frequency run with the
set value of C037.
Note:
⑴
This function is only valid when C024 is set to 1, i.e.externally
controlled 4-steps.
⑵
Low, intermediate and high speed frequency are determined
by Frequency2,3, 4.
⑶
Accel/Decel time is determined by Accel/Decel select
terminals.