C082
Stall prevention
level during decel. 0~200
180
C083
Overtorque detect
level
0~200
000
C084
Overtorque detect
time
0.1~20.0
01.0
C085
Rated Motor Voltage *
220/380
C086
Rated Motor Current *
*
C087
Motor poles
02~60
04
C088
Rated Motor
Revolution
0~9999
1440
C089
Motor no-load
current
0~100
40
C090 Slip compensation 0~1.0
0.000
C091 DC braking voltage 0.0~20.0
2.0
C092 DC braking time at
starting
0.0~25.0
0.0
C093 DC braking time at
stopping
0.0~25.0
0.0
C094 Speed search time 0.0~20.0
5.0
C095 Speed search
current level
0~200
150
C096 Restart after
instantaneous stop 0~1
0
C097 Allowable power-
off time
0.1~5.0
0.5
C098
Number of
abnormal restart 00~10
00
C099 Auto voltage
regulation function 0:Invalid 1
:
Effective
1
C100 Auto torgue
compensation
0.0~10.0
2.0
Parameter and Function List (Part 6)