HLP-C
+
Inverters
is between -5
℃
and 40
℃
and whether the installation
environment has good ventilation.
● Check whether the humidity is kept below 90%(no
condensation).
● Check whether the motor makes unusual noises or abnormal
vibration in running. (The inverter should not be installed in a
place with high vibration.)
● Please make periodical cleaning of the ventholes.
(3) Faults Information and Troubleshooting
HLP-C
+
series is relatively perfective with the protection
functions of overload, interphase short circuit, earthing short
circuit, undervoltage, overheat and overcurrent., etc. When a
protection function happens with the inverter please check the
resons of fault according to the information listed in the table
below. After the disposal restart the running. If the fault cannot
be disposed please contact the local distributor.
Fault
Display
Fault
Contents &
Description
Disposal methods
Overcurrent
at accel
⒈
Check whether the motor has got
short circuit or partial short circuit
and whether the output wire is good.
⒉
Extend the acceleration time.
⒊
The configuration of the inveter is
not reasonable and its capacity should
be increased.
⒋
Lower the torque and increase the
set value
Overcurrent
at constant
speed
⒈
Check whether the motor has
got short circuit and whether the
insulation of the output wires is good.
⒉
Check whether the motor is rotating
with some external jamming force
and whether there is a sudden change
of mechanical load.