HLP-C
+
Inverters
Multi-function Terminals
Results
Multi-
speed 1
Multi-
speed 2
Multi-
speed 3
OFF
OFF
OFF
Main frequency and frequency
are determined by C000 or
potentiometer.
ON
OFF
OFF
Multi-speed 1 and frequency are
determined by C035.
OFF
ON
OFF
Multi-speed 2 and frequency are
determined by C036.
ON
ON
OFF
Multi-speed 3 and frequency are
determined by C0375.
OFF
OFF
ON
Multi-speed 4 and frequency are
determined by C038.
ON
OFF
ON
Multi-speed 5 and frequency are
determined by C039.
OFF
ON
ON
Multi-speed 6 and frequency are
determined by C040.
ON
ON
ON
Multi-speed 7 and frequency are
determined by C041.
Note:
(1) To realize Excternal control 8-Speed Steps it is only valid
when Multi-input is set for Multi-speed 1, 2, 3 and C024 is set to 2.
(2) By using Multi-speed 1, 2, 3 they can make up 7- Speed
Steps. Adding the main frequency it will compose the setting of
8-Speed Steps.
(3) The frequencies of Step 1 ~ Step 7 are determined by
C035~C41.
(4) Each Acel/Decel Time is determined by the external multi-
function terminal.
(5) The directions of each program running are determined by
the external multi-function terminals.
(6) The main frequency can be given in two ways. One method
is to set it by C000 and another is to set it by the potentiometer.
When C013 is set to 1 the frequency of Main Frequency is given
by the potentiometer of the panel or external analog quantiy.
(7) The common use of Multi-speed and analog quantity is only