- -
HLP-C
+
Inverters
C004 Max. Voltage
Set Range
:
0.1~255/510V Unit
:
0.1V Factory Setting
:
220/380
This parameter can set any intermediate voltage in the V/F
curve. If it is set improperly, it will cause motor over current or
deficit torque, or even an inverter tripping.
This set value is limited by the max voltage value.
C005 Base Frequency
Set Range:0.01~600.00Hz
Unit:0.1Hz Factory Setting:50.00/60.00
C006 Intermediate voltage
Set Range
:
0.1~255/510V
Unit
:
0.1V
Factory Setting
:
*
C007 Intermediate Frequency
Set Range
:
0.01~600.00Hz Unit
:
0.01Hz
Factory Setting
:
*
This parameter can set any intermediate frequency in the V/F
curve. If it is set improperly, it will cause motor over current or
deficit torque, or even an inverter tripping.
This set value is limited by the setting of base frequency.
C008 Voltage at Lower Frequency
Set Range:0.1~*
Unit:0.1V
Factory Setting:*
This parameter can set the lowest starting voltage in the V/F
curve.
This setting value is limited by the voltage at the highest
operating frequency.
C009 Min. Frequency
Set Range:0.1~20.00Hz
Unit:0.01Hz
Factory Setting:*
This parameter sets the lowest starting frequency in the V/F
curve.
C010 Highest Running Frequency
Set Range:10.0~600.0Hz
Unit:0.01Hz
Factory Setting:
50.00/60.00