HLP-C
+
Inverters
up and the factory If the value has not been set properly due
to some reasons or the value is abnormal it can be set to 08 to
restore the factory setting and then reset again.
Items 0~4: They can be monitored, but not set.
C129 Voltage Up Time during Speed Search
Set Range
:
0.1~10.0S
Unit
:
0.1
Unit
:
0.5
When the starting method of the inverter is set to speed search
there is a process of voltage increase during the speed search.
Whhen the voltage is increae rapidly the current will be high
and the searching process will be fast. When the voltage is up
slowly the current will be low and the searching process will be
slow. Generally the value is set less for the machine with smallr
power and set more fir the machine with larger power.
C130 Stall & Decel Time during Running
Set Range
:
0.1~25.5S
Unit
:
0.1
Factory Setting
:
2.5
Set the speed of frequency decrease for stall prevention at
constant speed.
C131 Fault Reset Time
Set Range
:
0.2~25.0S
Unit
:
0.1
Factory Setting
:
1.0
When the inverter is set to fault restart and if theinverter has
fault trip and the time exceeds the setting of C131, the inverter
will restart. Pay attention to the safety when using this function.
C132 Counter Memory for Power-off
Set Range
:
0~1
Unit
:
1
Factory Setting
:
0
0
:
not memorized. 1
:
memorized.
*
: