3.5.6 Machine Interface Signal
No.
Signals
involved
Item
Contents
1
+/-ELS
DLS
OLS
[Input circuit form]
Input from servo driver
EXTPOW,
EXTGND
[[Power supply connection for
sensor]
Connected to the sensor’s +24V, GND terminals.
2
+/-ELS
[Over-travel sensor signal]
Signal polarity is set by G9003 initial setting (RENV1-b9) (Initial value:
NC)
DLS
[Deceleration sensor signal] /
[Counter clear/Counter latch]
See the next page, Note 2.
Signal polarity is set by G9003 initial setting (RENV1-b6) (Initial value: NC)
OLS
[Sensor origin signal]
Signal polarity is set by G9003 initial setting (RENV1-b7) (Initial value: NC)
Also, when using SVRDY, the mode register initial setting must be set to:
MDR-
b13 = ‘0’
Table 3.5-8 Machine I/F circuit
Module side
+24V
+24V
GND
EXTGND
EXTPOW
+/-ELS-OLS
Vcc
OU
T
GN
D
Axis sensor
4.4K
Machine I/F connector
Power supply terminal