26
2.2.6 Input and Output Port Circuit Types
Input circuit
Output circuit
Rated input voltage: DC12V-24V
Rated load voltage: DC12V-24V
Rated input current: 5mA/point
Rated load current: 30mA/point or less
Figure 2.2-6 Input and output port circuits
(1)
Connection example of an input circuit
Figure 2.2-7 Connection to sink type
(2)
Connection example of an output circuit
Figure 2.2-8 Connection example of an output circuit
EXTPOW
IN 1
IN 4
R
3kΩ
R
3
kΩ
Vcc
R
Vcc
R
TLP280-4
TLP280-4
F
F
Board side
External circuit
Switch
Open collector
transistor
External
power supply
(DC24V)
EXTPOW
OUT 1
OUT 4
R
TLP281-4
R
TLP281-4
R
33kΩ
R
33kΩ
TD62084AF
TD62084AF
EXTGND
Load
Load
External power
supply
(DC24V)
Board side
External circuit
TLP280-4
TLP280-4
Vcc
Vcc
R
R
F R
F R
R
33k
Ω
R
33k
Ω
R TLP281-4
R TLP281-4
TD62084AF
TD62084AF
3k
Ω
3k
Ω
EXTPOW
IN 1
IN 4
EXTPOW
OUT 1
OUT 4
EXTGND
Содержание motionCAT HCPCI-MNT720M
Страница 1: ...Motion Network System motionCAT series User s Manual Introduction Hivertec inc http www hivertec co jp...
Страница 3: ......
Страница 12: ...1 Warnings and Precautions...
Страница 20: ...9 1 motionCAT Installation...
Страница 109: ...98 4 Installation Guide...
Страница 118: ...107 5 Device Driver Installation...
Страница 122: ...111 6 Trial Operation...
Страница 145: ...134 7 Accessories...
Страница 147: ...136 8 Glossary...
Страница 161: ...150 9 Connections to Drivers Supplied by Manufacturers...