154
9.4 Hitachi Industrial Equipment Systems AD3
Figure 9.4-1 Hitachi Industrial Equipment Systems AD3
AD3 amplifier side
PLSP
PLSN
SIGP
SIGN
A-phase
Encoder signal output
B-phase
OAP
OAN
OBP
OBN
SRD
ALM
INP
BRK
From EXTGND
+24V
BRA
BR
A
L
Motion module side
CWN
CCWP
CCWN
From EXTPOW
From EXTGND
EXTGND
INPOS
INPOS
SVRDY
SVALM
SVBRK
AP
AN
BP
BN
Servo I/F connector
Machine I/F connector
(Other wiring for sensor etc. omitted)
CWP
2
3
4
5
20
21
22
23
17
32
33
15
16
6, 7, 8, 26
SVBRK
EXTGND
6
10
Note: SVBRK in the diagram is for reference when using
brake release function.
BRA is an auxiliary relay.
For details, see the AD3
series manual.
CER
PLC
4.7K
4.7K
SON
GCH
RS
SVCTRCL
SVON
EXTPOW (+24V)
SVGAIN
SVRST
EXTGND
11
10
12
13
29
35
TL
30
SVTL
CM2
CM2
I/O connector
Z-phase
OZP
OZN
ZP
ZN
24
25
General-purpose
output port 0
General-purpose
output port 3
General-purpose
output port 1
General-purpose
output port 2
From G9003
To G9003
From G9003
To G9003
Servo ON
Gain switching
Servo alarm reset
Servo ready
Servo alarm
INP (Inposition)
Torque limitation
(normally unused)
Brake signal
(normally unused)
Error pulse clear
Command pulse-train
Case
150
150
+24V power supply
To EXTGND
To EXTGND
To EXTPOW
To EXTPOW
24V
Power supply terminal
GND
GND
Содержание motionCAT HCPCI-MNT720M
Страница 1: ...Motion Network System motionCAT series User s Manual Introduction Hivertec inc http www hivertec co jp...
Страница 3: ......
Страница 12: ...1 Warnings and Precautions...
Страница 20: ...9 1 motionCAT Installation...
Страница 109: ...98 4 Installation Guide...
Страница 118: ...107 5 Device Driver Installation...
Страница 122: ...111 6 Trial Operation...
Страница 145: ...134 7 Accessories...
Страница 147: ...136 8 Glossary...
Страница 161: ...150 9 Connections to Drivers Supplied by Manufacturers...