Chapter 8 List of Data Settings
8 - 3
8.4 Extended Function Mode
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
A001
Frequency source setting
00 (keypad potentiometer) (*1), 01 (control circuit terminal block), 02 (digital
operator), 03 (RS485), 04 (option 1), 05 (option 2), 06 (pulse-string input), 07
(easy sequence), 10 (operation function result)
01
¯
¯
4-8
A002
Run command source setting
01 (control circuit terminal block), 02 (digital operator), 03 (RS485), 04 (option 1),
05 (option 2)
01
¯
¯
4-8
A003
Base frequency setting
30. to "maximum frequency " (Hz)
50.
¯
¯
A203
Base frequency setting, 2nd motor
30. to "maximum frequency, 2nd motor" (Hz)
50.
¯
¯
A303
Base frequency setting, 3rd motor
30. to "maximum frequency, 3rd motor" (Hz)
50.
¯
¯
4-11
A004
Maximum frequency setting
30. to 400. (Hz)
50.
¯
¯
A204
Maximum frequency setting, 2nd motor
30. to 400. (Hz)
50.
¯
¯
Basic set
tings
A304
Maximum frequency setting, 3rd motor
30. to 400. (Hz)
50.
¯
¯
4-11
A005
[AT] selection
00 (switching between O and OI terminals), 01 (switching between O and O2
terminals), 02 (switching between O terminal and keypad potentiometer) (*1), 03
(switching between OI terminal and keypad potentiometer) (*1), 04 (switching
between O2 and keypad potentiometer) (*1)
00
¯
¯
A006
[O2] selection
00 (single), 01 (auxiliary frequency input via O and OI terminals) (nonreversible),
02 (auxiliary frequency input via O and OI terminals) (reversible), 03 (disabling O2
terminal)
03
¯
¯
4-12
A011
[O]-[L] input active range start frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A012
[O]-[L] input active range end frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A013
[O]-[L] input active range start voltage
0. to "[O]-[L] input active range end voltage" (%)
0.
¯
{
A014
[O]-[L] input active range end voltage
"[O]-[L] input active range start voltage" to 100. (%)
100.
¯
{
A015
[O]-[L] input active range start frequency
selection
00 (external start frequency), 01 (0 Hz)
01
¯
{
4-14
A016
External frequency filter time const.
1. to 30. or 31. (500 ms filter ±0.1 Hz with hysteresis)
31.
¯
{
4-15
Analog input
and o
the
rs
A017
Easy sequence function selection
00 (disabling), 01 (enabling)
00
¯
¯
4-95
A019
Multispeed operation selection
00 (binary: 16 speeds selectable with 4 terminals), 01 (bit: 8 speeds selectable
with 7 terminals)
00
¯
¯
A020
Multispeed frequency setting
0.0 or “start frequency” to “maximum frequency” (Hz)
0.00
{
{
A220
Multispeed frequency setting, 2nd motor
0.0 or “start frequency” to “maximum frequency, 2nd motor” (Hz)
0.00
{
{
A320
Multispeed frequency setting, 3rd motor
0.0 or “start frequency” to “maximum frequency, 3rd motor” (Hz)
0.00
{
{
A021
Multispeed 1 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz)
0.00
{
{
A022
Multispeed 2 setting
0.0 or “start frequency” to “2nd maximum frequency” (Hz)
0.00
{
{
A023
Multispeed 3 setting
0.0 or “start frequency” to “3rd maximum frequency” (Hz)
0.00
{
{
A024
Multispeed 4 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A025
Multispeed 5 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A026
Multispeed 6 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A027
Multispeed 7 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A028
Multispeed 8 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A029
Multispeed 9 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A030
Multispeed 10 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A031
Multispeed 11 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A032
Multispeed 12 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A033
Multispeed 13 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A034
Multispeed 14 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
A035
Multispeed 15 setting
0.0 or “start frequency” to “n-th maximum frequency” (Hz)
0.00
{
{
4-47
A038
Jog frequency setting
"Start frequency" to 9.99 (Hz)
1.00
{
{
M
u
lt
ispeed ope
ra
ti
on
an
d jogging
A039 Jog
stop
mode
00 (free-running after jogging stops [disabled during operation]), 01 (deceleration
and stop after jogging stops [disabled during operation]), 02 (DC braking after
jogging stops [disabled during operation]), 03 (free-running after jogging stops
[enabled during operation]), 04 (deceleration and stop after jogging stops [enabled
during operation]), 05 (DC braking after jogging stops [enabled during operation])
00
¯
{
4-49
*1 This setting is valid only when the OPE-SR is connected.
Содержание SJ700B SERIES
Страница 15: ...Contents xiii Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 45: ......
Страница 59: ......
Страница 223: ......
Страница 237: ......
Страница 245: ......
Страница 250: ...Chapter 7 Specifications 7 5 SJ700B 185 to 300HFF SJ700B 370HFF 5 Cable hole φ25 3 Cable hole 42 x 42 5 ...
Страница 251: ...Chapter 7 Specifications 7 6 SJ700B 450 to 550HFF 5 Cable hole φ41 ...
Страница 253: ......