Chapter 8 List of Data Settings
8 - 4
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
A041
Torque boost method selection
00 (manual torque boost), 01 (automatic torque boost)
00
¯
¯
A241
Torque boost method selection,
2nd motor
00 (manual torque boost), 01 (automatic torque boost)
00
¯
¯
A042
Manual torque boost value
0.0 to 20.0 (%)
1.0
{
{
A242
Manual torque boost value, 2nd
motor
0.0 to 20.0 (%)
1.0
{
{
A342
Manual torque boost value, 3rd
motor
0.0 to 20.0 (%)
1.0
{
{
A043
Manual torque boost frequency
adjustment
0.0 to 50.0 (%)
5.0
{
{
A243
Manual torque boost frequency
adjustment, 2nd motor
0.0 to 50.0 (%)
5.0
{
{
A343
Manual torque boost frequency
adjustment, 3rd motor
0.0 to 50.0 (%)
5.0
{
{
4-18
A044
V/F characteristic curve selection,
1st motor
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control), 04 (0Hz-range sensorless
vector), 05 (vector with sensor)
00
¯
¯
A244
V/F characteristic curve selection,
2nd motor
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control), 04 (0Hz-range sensorless
vector)
00
¯
¯
A344
V/F characteristic curve selection,
3rd motor
00(VC), 01(VP)
00
¯
¯
4-16
A045
V/f gain setting
20. to 100. (%)
100.
{
{
4-15
A046
Voltage compensation gain setting
for automatic torque boost. 1st
motor
0. to 255.
100.
{
{
A246
Voltage compensation gain setting
for automatic torque boost, 2nd
motor
0. to 255.
100.
{
{
A047
Slippage compensation gain
setting for automatic torque boost,
1st motor
0. to 255.
100.
{
{
V/
f char
ac
te
ri
s
tic
A247
Slippage compensation gain
setting for automatic torque boost,
2nd motor
0. to 255.
100.
{
{
4-18
A051
DC braking enable
00 (disabling), 01 (enabling), 02 (set frequency only)
00
¯
{
A052
DC braking frequency setting
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.50
¯
{
A053
DC braking wait time
0.0 to 5.0 (s)
0.0
¯
{
A054
DC braking force during
deceleration
0. to 70. (%)
0.
¯
{
A055
DC braking time for deceleration
0.0 to 60.0 (s)
0.0
¯
{
A056
DC braking/edge or level detection
for [DB] input
00 (edge operation), 01 (level operation)
01
¯
{
A057
DC braking force for starting
0. to 70.(%)
0.
¯
{
A058
DC braking time for starting
0.0 to 60.0(s)
0.0
¯
{
DC br
aking
A059
DC braking carrier frequency
setting
0.5 to 12.0(kHz)
3.0
¯
¯
4-20
A061
Frequency upper limit setting
0.00 or "1st minimum frequency limit" to "maximum frequency" (Hz)
0.00
¯
{
A261
Frequency upper limit setting, 2nd
motor
0.00 or "2nd minimum frequency limit" to "maximum frequency, 2nd motor" (Hz)
0.00
¯
{
A062
Frequency lower limit setting
0.00 or "start frequency" to "maximum frequency limit"
(Hz)
0.00
¯
{
A262
Frequency lower limit setting, 2nd
motor
0.00 or "start frequency" to "maximum frequency, 2nd motor limit"
(Hz)
0.00
¯
{
4-24
A063
Jump (center) frequency setting 1
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A064
Jump (hysteresis) frequency width
setting 1
0.00 to 10.00 (Hz)
0.50
¯
{
A065
Jump (center) frequency setting 2
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A066
Jump (hysteresis) frequency width
setting 2
0.00 to 10.00 (Hz)
0.50
¯
{
A067
Jump (center) frequency setting 3
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A068
Jump (hysteresis) frequency width
setting 3
0.00 to 10.00 (Hz)
0.50
¯
{
A069
Acceleration stop frequency setting 0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
Fr
equency u
pper
/l
ower
lim
it
and
jum
p
fr
equency
A070
Acceleration stop time frequency
setting
0.0 to 60.0 (s)
0.0
¯
{
4-25
A071
PID Function Enable
00 (disabling), 01 (enabling), 02 (enabling inverted-data output)
00
¯
{
A072
PID proportional gain
0.2 to 5.0
1.0
{
{
A073
PID integral time constant
0.0 to 999.9, 1000. to 3600. (s)
1.0
{
{
A074
PID derivative gain
0.00 to 99.99, 100.0 (s)
0.00
{
{
A075
PV scale conversion
0.01 to 99.99
1.00
¯
{
A076
PV source setting
00 (input via OI), 01 (input via O), 02 (external communication), 03 (pulse-string frequency
input), 10 (operation result output)
00
¯
{
A077
Output of inverted PID deviation
00(OFF), 01 (ON)
00
¯
{
A078
PID variation range
0.0 to 100.0 (%)
0.00
¯
{
PI
D contr
o
l
A079
PID feed forward selection
00 (disabled), 01 (O input), 02 (OI input), 03 (O2 input)
00
¯
{
4-26
Содержание SJ700B SERIES
Страница 15: ...Contents xiii Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 45: ......
Страница 59: ......
Страница 223: ......
Страница 237: ......
Страница 245: ......
Страница 250: ...Chapter 7 Specifications 7 5 SJ700B 185 to 300HFF SJ700B 370HFF 5 Cable hole φ25 3 Cable hole 42 x 42 5 ...
Страница 251: ...Chapter 7 Specifications 7 6 SJ700B 450 to 550HFF 5 Cable hole φ41 ...
Страница 253: ......